EL6910
EL6910 | TwinSAFE Logic
The EL6910 TwinSAFE Logic can establish up to 212 connections to other TwinSAFE devices. Several EL6910 can be cascaded in a TwinSAFE network with up to 65,535 TwinSAFE devices. The EL6910 EtherCAT Terminal features certified safety function blocks, which are configured according to the application. Safety functions such as emergency stop, safety door monitoring, two-hand control, etc. can thus easily be selected and linked. All blocks can be freely connected among each other and are complemented by operators such as AND, OR, etc.
Specification: | link unit between safe input and output signals |
Protocol: | TwinSAFE/Safety over EtherCAT |
Cycle time: | approx. 1 ms/according to project size |
Fault response time: | ≤ watchdog time (parameterisable) |
Current consumption power contacts: | – |
Current consumption E-bus: | typ. 160 mA |
Installation position: | horizontal |
Safety standard: | EN ISO 13849-1:2015 (Cat. 4, PL e) and EN 61508:2010 (SIL 3) |
Weight: | approx. 50 g |
Protection class: | IP 20 |
Approvals/markings: | Overview of TwinSAFE Certifications (PDF) |
Download EtherCAT slave information (ESI): | ESI config file ELx9xx (ZIP) |
ТН ВЭД: | |
Страна происхождения: | |
EAN: | |
Вес: | 0,00 kg |
Длина: | 0,00 m |
Ширина: | 0,00 m |
Высота: | 0,00 m |