541993
LB6008A
Digital Output with Shutdown Input
8-channel, Galvanic group isolation, Installation in Zone 2 or safe area, Module can be exchanged under voltagepa. The device features 8 independent channels. The device can be used to drive low power solenoids, sounders, or LEDs. Open and short-circuit line faults are detected. The outputs are galvanically isolated from the bus and the power supply. The outputs can be switched off via a contact. This can be used for bus-independent safety applications.
| Occupied slots: | 2 |
| Safety Integrity Level (SIL): | SIL 2 |
| Connection: | backplane bus |
| Rated voltage: | 12 V DC , only in connection with the power supplies LB9*** |
| Power dissipation: | 2.35 W |
| Power consumption: | 2.35 W |
| Connection: | backplane bus |
| Interface: | manufacturer-specific bus to standard com unit |
| Number of channels: | 8 |
| Suitable field devices: Field device: | Solenoid Valve |
| Suitable field devices: Field device [2]: | audible alarm |
| Suitable field devices: Field device [3]: | visual alarm |
| Connection: | channel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V: 9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16- |
| Current limit: | 8 mA |
| Open loop voltage: | 20 V |
| Line fault detection: | can be switched on/off for each channel via configuration tool |
| Suitable field devices: Test current: | 0.33 mA |
| Suitable field devices: Short-circuit: | < 300 Ω |
| Suitable field devices: Open-circuit: | > 50 kΩ |
| Response time: | 20 ms (depending on bus cycle time) |
| Watchdog: | within 0.5 s the device goes in safe state, e.g. after loss of communication |
| LED indication: | LED green: supply LED red: line fault , red flashing: communication error |
| Coding: | optional mechanical coding via front socket |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1 |
| Electromagnetic compatibility: | NE 21 |
| Degree of protection: | IEC 60529 |
| Environmental test: | EN 60068-2-14 |
| Shock resistance: | EN 60068-2-27 |
| Vibration resistance: | EN 60068-2-6 |
| Damaging gas: | EN 60068-2-42 |
| Relative humidity: | EN 60068-2-56 |
| Ambient temperature: | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) |
| Storage temperature: | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity: | 95 % non-condensing |
| Shock resistance: | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance: | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas: | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection: | IP20 when mounted on backplane |
| Connection: | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
| Mass: | approx. 160 g |
| Dimensions: | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
| Output: Voltage: | 28 V |
| Output: Current: | 13.5 mA |
| Output: Power: | 376 mW |
| Output: Internal capacitance: | 3.6 nF |
| Output: Internal inductance: | 0 mH |
| Certificate: | PF 08 CERT 1234 X |
| Output: Marking: | II 3 G Ex nA [ic] IIC T4 Gc |
| Galvanic isolation: Output/power supply, internal bus: | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 |
| ATEX approval: | PF 08 CERT 1234 X |
| IECEx approval: | BVS 09.0037X |
| Directive conformity: Approved for: | Ex nA [ic] IIC T4 Gc |
| EAC approval: | Russia: RU C-IT.MIII06.B.00129 |
| Marine approval: Lloyd Register: | 15/20021 |
| Marine approval: DNV GL Marine: | TAA0000034 |
| Marine approval: American Bureau of Shipping: | T1450280/UN |
| Marine approval: Bureau Veritas Marine: | 22449/B0 BV |
| System information: | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. |
| Supplementary information: | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |