275874
VBA-4A-70MM
AS-Interface stack light module
The signal column module VBA-4A-70MM is an AS-Interface module with 4 virtually wearproof semiconductor relay outputs which can trigger up to 4 stages of a signal column. AS-Interface module for stack lightfa. The connection of the external auxiliary voltage and the AS-Interface takes place via screw terminals in the corresponding connection element which is easily fitted to the module via a bayonet system. The supply of the connected outputs can take place either from the internal power supply of the module (from AS-Interface) or via an external power source. Switching takes place via a sliding switch inside the element. The selection of the external power supply is indicated via an LED (AUX). The outputs are protected against reversal, overload and short circuit. An LED to indicate the AS-Interface voltage is available, another indicates errors in the AS-Interface communication. For parameterization there is an addressing jack in the element protected against external interference.
| Slave type: | A/B slave |
| AS-Interface specification: | V3.0 |
| Required master specification: | ≥ V3.0 |
| UL File Number: | E223176 |
| MTTFd: | 300 a |
| LED FAULT: | communication error / address is 0; LED red |
| LED AS-i: | AS-Interface voltage; LED green |
| LED AUX: | ext. auxiliary voltage UAUX ; LED green |
| Auxiliary voltage (output): | 20 ... 30 V DC PELV |
| Rated operating voltage: | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current: | ≤ 210 mA |
| Number/Type: | 4 semiconductor relay outputs |
| Supply: | from AS-Interface or from external auxiliary voltage as required UAUX |
| Voltage: | 21 ... 31 V |
| Current: | AS-interface: ≤ 200 mA for the stack light UAUX: ≤ 300 mA per light element |
| Profile: | S-7.A.7 |
| IO code: | 7 |
| ID code: | A |
| Data bits (function via AS-Interface): | input output |
| : D0: | - OUT1 |
| : D1: | - OUT2 |
| : D2: | - OUT3 |
| : D3: | - OUT4 |
| Parameter bits (programmable via AS-i): | function |
| : P0: | Communication monitoring P0 = 0 monitoring = off, the outputs maintain the status if communication fails P0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) |
| : P1: | not used |
| : P2: | not used |
| : P3: | not used |
| Ambient temperature: | -20 ... 50 °C (-4 ... 122 °F) |
| Degree of protection: | IP65 |
| Connection: | Bayonet system |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |