244226
HID2082
Temperature Converter
2-channel isolated barrier, 24 V DC supply (bus powered), Thermocouple, RTD or potentiometer input, Usable as signal splitter (1 input and 2 outputs), Linearized output 4 mA .. 20 mA, sink/source or 1 V .. 5 V, Sensor breakage detection, Configurable by PACTware, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511pa. This isolated barrier is used for intrinsic safety applications. This device accepts thermocouples (TC), millivolts, potentiometers, or resistance temperature detectors (RTD) from a hazardous area and converts them to an isolated, linearized analog output in the safe area. The outputs can be selected as a current source, current sink, or voltage source with DIP switches on the side panel. The device can also be configured as a signal splitter. Line fault detection of the field circuit is indicated by a red LED and an output on the fault bus. The fault conditions are monitored via a Fault Indication Board. The device is easily configured by the use of the PACTware configuration software. This device mounts on a HiD Termination Board.
| Signal type: | Analog input |
| Connection: | SL1: 1a(-), 1b(-); 2a(+), 2b(+) |
| Rated voltage: | 20.4 ... 30 V DC bus powered via Termination Board |
| Ripple: | within the supply tolerance |
| Current: | ≤ 95 mA at 20.4 V and ≤ 63 mA at 30 V |
| Power consumption: | ≤ 1.95 W |
| Connection side: | field side |
| Connection: | SL2: 5a(+), 1a(+), 1b(-), 5b(-); 7a(+), 3a(+), 3b(-), 7b(-) |
| RTD: | type Cu10, Cu50, Cu100, Pt10, Pt50, Pt100, Pt500, Pt1000, Ni100 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt50GOST, Pt1000GOST (P50353-92) |
| : Measuring current: | approx. 200 µA with RTD |
| : Types of measuring: | 2-, 3-, 4-wire connection |
| : Lead resistance: | max. 50 Ω per line |
| : Measurement loop monitoring: | sensor breakage, sensor short-circuit |
| Thermocouples: | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
| : Cold junction compensation: | at field terminals |
| : Measurement loop monitoring: | sensor breakage |
| Potentiometer: | 0.1 ... 20 kΩ |
| : Types of measuring: | 3-wire connection |
| Voltage: | selectable within the range -100 ... 100 mV |
| Input resistance: | min. 1 MΩ (-100 ... 100 mV) |
| Connection side: | control side |
| Connection: | SL1: 8a(+), 7a(-); 10a(+), 9a(-) |
| Output I, II: | analog, current or voltage output |
| : Current range: | 0/4 ... 20 mA |
| : Voltage range: | 0 ... 5 V or 1 ... 5 V (on 250 Ω, 0.1 % internal shunt) |
| : Fault signal: | downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43) |
| : Source: | load 0 ... 550 Ω , open-circuit voltage ≤ 18 V |
| : Sink: | Voltage across terminals 7 ... 30 V. If the current is supplied from a source > 20 V, series resistance of ≥ (V - 20)/0.0215 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 7)/0.0215 Ω. |
| Connection: | SL1: 6b |
| Output type: | open collector transistor (internal fault bus) |
| Reaction time: | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms |
| Display elements: | LEDs |
| Control elements: | DIP-switch |
| Configuration: | via DIP switches via PACTware |
| Labeling: | space for labeling at the front |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1:2013 (industrial locations) |
| Electromagnetic compatibility: | NE 21:2006 For further information see system description. |
| Degree of protection: | IEC 60529:2001 |
| Ambient temperature: | -20 ... 60 °C (-4 ... 140 °F) |
| Degree of protection: | IP20 |
| Mass: | approx. 140 g |
| Dimensions: | 18 x 106 x 128 mm (0.7 x 4.2 x 5 inch) |
| Mounting: | on Termination Board |
| EU-Type Examination Certificate: | CESI 02 ATEX 086 |
| Electromagnetic compatibility: Marking: | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC , (-20 °C ≤ Tamb ≤ 60 °C) |
| Certificate: | PF 11 CERT 2109 X |
| Electromagnetic compatibility: Marking: | II 3G Ex nA nC IIC T4 |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
| CSA approval: Control drawing: | 366-017CS-12 (cCSAus) |
| IECEx approval: | IECEx TUN 04.0012 |
| CSA approval: Approved for: | [Ex ia] IIC |
| ECCN: | |
| Kraj pochodzenia: | SG |
| EAN: | |
| Waga: | 0,15 kg |