Opis

This isolated barrier is used for intrinsic safety applications. It monitors for an overspeed or underspeed condition of a discrete signal (NAMUR sensor/ mechanical contact) from a hazardous area by comparing the input frequency to the user programmed reference frequency. 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Input frequency 1 mHz .. 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511pa. An overspeed or underspeed condition is signaled via the relay outputs. Line fault detection of the field circuit is indicated by a red LED and relay. The start-up override feature sets relay outputs to default conditions programmed by the user for up to 1,000 seconds. The unit is easily programmed by the use of a keypad located on the front of the unit. For additional information, refer to the manual and www.pepperl-fuchs.com.

Parametry techniczne

Signal type: Digital Input
Safety Integrity Level (SIL): SIL 2
Connection: terminals 23, 24
Rated voltage: 115 V AC +/- 10 %
Rated current: 30 mA
Power dissipation/power consumption: ≤ 2 VA / 2 VA
Connection side: field side
Connection: Input I: intrinsically safe: terminals 1+, 3- Input II: non-intrinsically safe: terminals 13+, 14-
Input I: acc. to EN 60947-5-6 (NAMUR), see system description for electrical data
: Pulse duration: > 50 µs
: Input frequency: 0.001 ... 5000 Hz
: Line fault detection: breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input II: startup override: 1 ... 1000 s, adjustable in steps of 1 s
: Active/Passive: I > 4 mA (for min. 100 ms)/ I < 1 mA
: Open circuit voltage/short-circuit current: 18 V / 5 mA
Connection side: control side
Connection: output I: terminals 10, 11, 12 output II: terminals 16, 17, 18
Output I, II: signal, relay
: Contact loading: 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
: Mechanical life: 5 x 107 switching cycles
: Energized/De-energized delay: approx. 20 ms / approx. 20 ms
Input I: Measurement range: 0.001 ... 5000 Hz
Input I: Resolution: 0.1 % of the measurement value , ≥ 0.001 Hz
Input I: Accuracy: 0.1 % of the measurement value , > 0.001 Hz
Input I: Measuring time: < 100 ms
Input I: Influence of ambient temperature: 0.003 %/K (30 ppm)
Output I, II: Response delay: ≤ 200 ms
Input I/other circuits: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachother: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Start-up override/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display elements: LEDs , display
Control elements: Control panel
Configuration: via operating buttons
Labeling: space for labeling at the front
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EU: EN 61010-1:2010
Electromagnetic compatibility: NE 21:2006
Degree of protection: IEC 60529:2001
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Degree of protection: IP20
Connection: screw terminals
Mass: 300 g
Dimensions: 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificate: TÜV 99 ATEX 1408
Low voltage: Marking: II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Supply: Maximum safe voltage: 253 V AC (Attention! Um is no rated voltage.)
Input I: terminals 1+, 3-: Ex ia
Supply: Voltage Uo: 10.1 V
Supply: Current Io: 13.5 mA
Supply: Power Po: 34 mW (linear characteristic)
Input II: terminals 13+, 14- non-intrinsically safe
Supply: Maximum safe voltage Um: 40 V (Attention! The rated voltage can be lower.)
Output I, II: terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Supply: Maximum safe voltage: 253 V (Attention! The rated voltage can be lower.)
Supply: Contact loading: 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471)
Certificate: TÜV 02 ATEX 1885 X
Supply: Marking: II 3G Ex nA nC IIC T4 Gc
Output I, II: Contact loading: 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load
Galvanic isolation: Input I/other circuits: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
FM approval: Control drawing: 16-538FM-12
UL approval: E223772
IECEx approval: IECEx certificate: IECEx TUN 03.0000
IECEx approval: IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Parametry logistyczne

ECCN:
Kraj pochodzenia: SG
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m