131000
HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module
Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PApa. Designed as a plug-in module for the FieldConnex® Power Hub, this Advanced Diagnostic Module (ADM) is a comprehensive measurement tool for the physical layer of up to four fieldbus segments. It's passive input circuits leave the physical layer untouched for exact data. The ADM detects gradual or sudden changes and helps trace even intermittent malfunctions. The ADM supports commissioning, online monitoring and troubleshooting. It can be integrated tightly into the DCS and PAM via a separate diagnostic bus, making the fieldbus physical layer itself a managable asset. Configuration tools automate setup of the ADM and of selected DCS. The Diagnostic Manager is the software for display and operation from the safety of the control room. The Professional Edition provides powerful functions and wizards simplifying and automating work procedures: an embedded expert system, a data historian, and a built-in oscilloscope (see datasheet DTM-FC.AD*).
| Design / Mounting: | Motherboard based |
| Rated voltage: | 19.2 ... 35 V |
| Rated current: | 110 ... 30 mA |
| Power dissipation: | max. 2 W |
| Number of segments: | 4 |
| Fieldbus type: | FOUNDATION Fieldbus/PROFIBUS PA |
| Rated voltage: | 9 ... 32 V |
| LED PRI PWR: | green: on, primary bulk power supply connected |
| LED SEC PWR: | green: on, secondary bulk power supply connected |
| LED Seg 1...4: | yellow: bus activity; red 2 Hz flashing: alarm; red: hardware error |
| Fault signal: | VFC alarm 1 A, 50 V DC, normally closed |
| DIP switch: | diagnostic address 1...247, binary coded |
| Interface type: | diagnostic bus: RS 485 |
| Fieldbus segment/Fieldbus segment: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Fieldbus segment/Supply: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1:2013 |
| Electromagnetic compatibility: | NE 21:2011 |
| Degree of protection: | IEC 60529 |
| Shock resistance: | EN 60068-2-27 |
| Vibration resistance: | EN 60068-2-6 |
| Ambient temperature: | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity: | < 95 % non-condensing |
| Shock resistance: | 15 g 11 ms |
| Vibration resistance: | 1 g , 10 ... 150 Hz |
| Pollution degree: | max. 2, according to IEC 60664 |
| Corrosion resistance: | acc. to ISA-S71.04-1985, severity level G3 |
| Connection type: | motherboard specific |
| Core cross-section: | motherboard specific |
| Housing material: | Polycarbonate |
| Housing width: | 18 mm |
| Housing height: | 106 mm |
| Housing depth: | 128 mm |
| Degree of protection: | IP20 |
| Mass: | approx. 100 g |
| Mounting: | motherboard mounting |
| Mating cycles: | 100 |
| Certificate: | TÜV 04 ATEX 2500 X |
| Electromagnetic compatibility: Marking: | II 3 G Ex nA IIC T4 Gc |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 |
| FM approval: FM certificate: | FM 19 US 0015 X and FM 19 CA 0011 X |
| FM approval: FM marking: | AEx/Ex ec IIC T4 |
| IECEx approval: IECEx certificate: | IECEx TUN 13.0038X |
| IECEx approval: IECEx marking: | Ex nA IIC T4 Gc |
| Marine approval: | DNV A-14038 |
| Patents: | This product may be covered by the following patent: US7,698,103 |
| Supplementary information: | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| ECCN: | |
| Kraj pochodzenia: | SG |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |