Pepperl+Fuchs 240603

ELS-1

Enclosure Leakage Sensor

Bajo pedido. Envíenos un correo electrónico para consultar el precio y la disponibilidad.
"ucnguBrctvdgcxgt0eqo"

Descripción

Housing leakage sensor, for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PApa

Parámetros técnicos

Design / Mounting: Cabinet installation
Rated voltage: 9 ... 32 V
Power dissipation: 670 mW
Self current consumption: max. 6 mA
LED ERR: green flashing: status OK , red flashing: maintenance required
Internal measurement cycle: in normal state 30 s in alarm state 300 s
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013
Electromagnetic compatibility: NE 21:2006
Degree of protection: IEC 60529
Fieldbus standard: IEC 61158-2
Climatic conditions: IEC 60721
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Ambient temperature: -40 ... 80 °C (-40 ... 176 °F)
Storage temperature: -40 ... 85 °C (-40 ... 185 °F)
Relative humidity: 100 %
Shock resistance: 15 g 11 ms
Vibration resistance: 1 g , 10 ... 150 Hz
Life span: exposed to rain water 8760 h , exposed to sea water 1440 h
Connection type: two strands, length 180 mm with cable ferrules, PVC insulation
Core cross-section: 0.25 mm2
Housing material: Polycarbonate
Degree of protection: Electronic component IP67 connection IP00
Mass: 10 g
EU-Type Examination Certificate: SIRA 12 ATEX 2129X
Electromagnetic compatibility: Marking: II 1G Ex ia IIC T4
Electromagnetic compatibility: Voltage: 24 V
Electromagnetic compatibility: Internal capacitance: negligible 0 nF
Electromagnetic compatibility: Internal inductance: negligible 0 µH
Certificate: SIRA 12 ATEX 4154X
Electromagnetic compatibility: Marking: II 3G Ex nAc IIC T4 , II 3G Ex ic IIC T4
Electromagnetic compatibility: Voltage Ui: 33 V
Electromagnetic compatibility: Internal capacitance Ci: negligible 0 nF
Directive conformity: Directive 2014/34/EU: EN 60079-0:2011 Ed. 6 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007
Supplementary information: FISCO field device
UL approval: Control drawing: 116-B028
UL approval: Approved for: Class I, Division 1, Groups A, B, C, D, T4 , Class I, Division 2, Groups A, B, C, D, T4
UL approval: cULus: E326119
IECEx approval: IECEx SIR 12.0052X
UL approval: Approved for: Ex ia IIC T4 , Ex ic IIC T4 , Ex nAc IIC T4
Marine approval: DNV A-14038

Parámetros logísticos

ECCN:
País de origen: Singapur
EAN: 4050143063291
Peso: 0,01 kg
Longitud: 0,00 m
Anchura: 0,00 m
Altura: 0,00 m