Descripción

System board for Yokogawa ProSafe-RS, For 16-channel AI card SAI143, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pinpa

Parámetros técnicos

Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators
Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered
Ripple: ≤ 10 %
Fusing: 4 A , in each case for 16 modules
Power dissipation: ≤ 500 mW , without modules
Reverse polarity protection: yes
Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.
Output type: volt-free contact
Contact loading: 30 V DC , 1 A
Display elements: LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED flashes: power supply failure
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial locations)
Electromagnetic compatibility: NE 21:2012 For further information see system description.
Degree of protection: IEC 60529:2001
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -40 ... 70 °C (-40 ... 158 °F)
Degree of protection: IP20
Connection: Field side: explosion hazardous area: spring terminals , blue
Connection: Control side: non-explosion hazardous area: Yokogawa system connector, 40-pin
Connection: Supply: pluggable screw terminals , black
Connection: Fault output: pluggable screw terminals , black
Core cross-section: spring terminals: rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2
Material: housing: polycarbonate
Mass: approx. 650 g
Dimensions: 240 x 175 x 153 mm (9.45 x 6.9 x 6.02 inch) , height including module assembly
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-Type Examination Certificate: CESI 06 ATEX 022
Connection: Marking: II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Safe area: Maximum safe voltage: 250 V (Attention! Um is no rated voltage.)
Galvanic isolation: Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000
IECEx approval: IECEx CES 06.0003
Directive conformity: Approved for: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I

Parámetros logísticos

ECCN:
País de origen: SG
EAN:
Peso: 0,00 kg
Longitud: 0,00 m
Anchura: 0,00 m
Altura: 0,00 m