Pepperl+Fuchs 202305

VBG-PB-K30-D-S

AS-Interface Gateway/Safety Monitor

Bajo pedido. Envíenos un correo electrónico para consultar el precio y la disponibilidad.
"ucnguBrctvdgcxgt0eqo"

Descripción

Gateway with integrated Safety Monitorfa

Parámetros técnicos

AS-Interface specification: V3.0
PLC-Functionality: activateable
Duplicate address detection: from AS-Interface slaves
Earth fault detection: integrated
EMC monitoring: integrated
Diagnostics function: Extended function via display
Switch-on delay: < 10 s
Response delay: < 40 ms
UL File Number: E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
Safety Integrity Level (SIL): SIL 3
Performance level (PL): PL e
MTTFd: 200 a
B10d: 2 E+7
Display: Illuminated graphical LC display for addressing and error messages
LED PROFIBUS: PROFIBUS master detected; LED green
LED AS-i ACTIVE: AS-Interface operation normal; LED green
LED CONFIG ERR: configuration error; LED red
LED PRG ENABLE: autom. programming; LED green
LED POWER: voltage ON; LED green
LED PRJ MODE: projecting mode active; LED yellow
LED U AS-i: AS-Interface voltage; LED green
Switch SET: Selection and setting of a slave address
OK button: Mode selection traditional-graphical/confirmation
Button MODE: Mode selection PRJ-operation/save configuration/cursor
ESC button: Mode selection traditional-graphical/cancel
Insulation voltage: ≥ 500 V
Rated operating voltage: 26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC
Rated operating current: ≤ 300 mA from AS-Interface
Interface type: RS-485
Protocol: PROFIBUS DP V1
Transfer rate: 9.6 kBit/s / 12 MBit/s , Automatic baud rate detection
Interface type: RS 232, serial Diagnostic Interface
Transfer rate: 19,2 kBit/s
Interface type: Chip card slot
Number/Type: 2 EDM inputs: Inputs for external device monitoring circuits 1 and 2 (protection control) 2 Start inputs: Output circuits 1 and 2: Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Safety output: 2 x 2 output switch elements: Output circuits 1 and 2 max. contact loading: 3 A DC-13 at 30 V DC, 3 A AC-15 at 30 V AC
PROFIBUS: Sub-D interface
AS-Interface: spring terminals, removable
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Electromagnetic compatibility: EN 61000-6-2:2005, EN 61000-6-4:2007
Degree of protection: EN 60529:2000
Fieldbus standard: PROFIBUS according to DIN 19245 Part 3
AS-Interface: EN 62026-2:2013
Shock resistance: EN 61131-2:2004
Standards: EN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e)
UL approval: An isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device.
Ambient temperature: 0 ... 55 °C (32 ... 131 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Degree of protection: IP20
Connection: screw terminals
Mass: 800 g
Construction type: Low profile housing , Stainless steel

Parámetros logísticos

ECCN:
País de origen: Deutschland
EAN: 4050143023493
Peso: 0,90 kg
Longitud: 0,00 m
Anchura: 0,00 m
Altura: 0,00 m