200875
IC-KP2-2HB6-V15B
Control interface unit
Control interface unit IDENTControl Compact with interface for PROFIBUS DPfa
| Number of read/write heads: | max. 2 alternatively 1 read/write head and 1 trigger sensor |
| UL File Number: | E87056 |
| LED BUS: | green: Slave is at state "Data Exchange" red: Bus error |
| LED Diag: | No function |
| LEDs 1, 2: | Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed |
| LEDs CH1, CH2: | green: read head detected red: Configuration error |
| LED PWR/ERR: | green: power on red: Hardware fault |
| Rotary switch: | Address setting 00 ... 7E, FF (hexadecimal) BUS Address (high nibble): 0 ... 7, F BUS Address (low nibble): 0 ... F |
| Rated operating voltage: | 20 ... 30 V DC , PELV |
| Ripple: | ≤ 10 % at 30 V DC |
| Current consumption: | ≤ 4 A incl. read/write heads |
| Power consumption: | 2 W Without read/write heads |
| Galvanic isolation: | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff |
| Interface type: | PROFIBUS |
| Physical: | RS-485 |
| Protocol: | PROFIBUS DP acc. to EN 50170 |
| Transfer rate: | 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing |
| Interface type: | Diagnostic Interface |
| Physical: | RS 232 |
| Protocol: | ASCII |
| Transfer rate: | 38.4 kBit/s |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61000-6-2 EN 61000-6-4 |
| RoHS: Directive 2011/65/EU (RoHS): | EN 50581 |
| Degree of protection: | IEC 60529 |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Climatic conditions: | air humidity max. 96 % Salt spray resistant to EN 60068-2-52 |
| Shock and impact resistance: | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
| Degree of protection: | IP67 |
| Connection: | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M12 connector PROFIBUS: M12 connector, B-coded |
| Material: Housing: | powder coated aluminum |
| Installation: | screw fixing |
| Mass: | approx. 300 g |
| ECCN: | |
| País de origen: | SG |
| EAN: | |
| Peso: | 0,00 kg |
| Longitud: | 0,00 m |
| Anchura: | 0,00 m |
| Altura: | 0,00 m |