111534
VAS-2A-K12-U
Configuración con bloqueo MGB-L1HE-ARA... (bloqueo mediante fuerza de resorte) sin elementos de mando ni indicadores, M12
Bloqueo con monitorización de bloqueo. Posibilidad de conexión en serie con otros dispositivos AR (por ejemplo, CES-AR y CET-AR). Con conector M12. Con desbloqueo antipánico. Unicode
| AS-Interface specification: | V2.1 |
| Switch-on delay: | < 10 s |
| Response delay: | < 40 ms |
| UL File Number: | E198304 |
| Safety Integrity Level (SIL): | SIL 3 |
| Performance level (PL): | PL e |
| MTTFd: | 389 a |
| B10d: | 2 E+5 |
| LED green: | Off: contacts of the safety output (OSSD) open constantly lit: contacts of the safety output (OSSD) closed flashing: delay time running for Stop Category 1 |
| LED yellow: | off: - constantly lit: startup/restart lock active flashing: external test required |
| LED red: | Off: contacts of the safety output (OSSD) closed constantly lit: contacts of the safety output (OSSD) open flashing: error |
| LED POWER: | from: no power supply green, continuous illuminated: AS-Interface power supply available |
| LED AS-i: | from: normal operation red, continuous illuminated: communication error |
| Rated operating voltage: | 24 V DC ± 15 % Residual ripple ≤ 15 % 26.5 ... 31.6 V from AS-Interface |
| Rated operating current: | ≤ 200 mA ≤ 45 mA from AS-Interface |
| Surge protection: | overvoltage category III for rated operating voltage 300 V DC acc. to VDE 0110 Part 1 |
| Interface type: | RS 232, serial |
| Transfer rate: | 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits |
| Number/Type: | 2 opto-coupling inputs (high-active) "Start" and "protection control (EDM)", input currents about 10 mA at 24 V DC |
| Safety output: | 2 x 2 potential-free NO contacts, max. contact loading: 1 A DC-13 at 24 V DC, 3 A AC-15 at 230 V AC |
| Output type: | Signal output: PNP transistor output, 200 mA, short-circuit and reverse-polarity-proof |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 62026-2:2013 EN 61000-6-2:2006, EN 61000-6-4:2007 |
| Low voltage: Directive 2006/95/EC: | EN 60947-5-1:2005 |
| Machinery Directive: Directive 2006/42/EC: | EN 954-1:1996, EN 61496:2005, EN 60204-1:2006 |
| Degree of protection: | EN 60529:2000 |
| Electrical safety: | EN 50178:1998 |
| AS-Interface: | EN 62026-2:2013 |
| Functional safety: | ISO 13849-1:2008 (up to category 4/PL e), IEC 61508:2000/IEC 62061:2005 (up to SIL3) |
| Standards: | NFPA 79:2002 |
| Ambient temperature: | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature: | -30 ... 70 °C (-22 ... 158 °F) |
| Degree of protection: | IP20 (only for use in electrical operating rooms / switch cabinet suitable with minimum protection type IP54) |
| Connection: | screw terminals |
| Material: Housing: | Polyamide PA 66 , black |
| Mass: | 450 g |
| Mounting: | DIN rail mounting |
| ECCN: | |
| País de origen: | DE |
| EAN: | |
| Peso: | 0,00 kg |
| Longitud: | 0,00 m |
| Anchura: | 0,00 m |
| Altura: | 0,00 m |