0053813
BH5928.92/61 DC24V 1-10S
Emergency stop module with time delay BH 5928
According to. Performance Level (PL) e and category 4 to EN ISO 13849-1. SIL Claimed Level (SIL CL) 3 to IEC/EN 62061. Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511. Output: 3 NO or 2 NO, 1 NC instantaneous contacts and. 3 NO release delayed contacts. Single and 2-channel operation. Line fault detection on On-button,, when On-button is connected to S33-S34. Manual restart with button on S33-S34 or automatic restart with, bridge between S13-S14. With or without cross fault monitoring in the E-stop loop. LED indication for supply, channel 1/2 and release delayed contacts. Removable terminal strips. Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),. DIN 46 228-1/-2/-3/-4 or. 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3. Width. BH 5928: 45 mm. BI 5928: 67.5 mm
| Function: | Emergency stop module with time delay |
| Also suited as safety gate monitor: | + |
| Cat. / PL according to EN ISO 13849-1: | 4/e |
| SIL CL according to IEC/EN 62061: | 3 |
| 1- / 2-channel: | 1; 2 |
| Output contacts max.: | 3 s; 3 sv |
| Thermal current Ith max.: | 5 A |
| Cross fault detection: | + |
| Nominal voltage DC: | + |
| Nominal voltage AC/DC: | + |
| Approvals: | UL |
| Connection: | PS |
| Width: | 45 mm |
| Type: | BH 5928 |
| ECCN: | |
| País de origen: | |
| EAN: | |
| Peso: | 0,43 kg |
| Longitud: | 0,00 m |
| Anchura: | 0,00 m |
| Altura: | 0,00 m |