ZRX8
Dual Channel Zener barrier in ATEX Zone 2/22
Compact 22.5 mm format Suitable for RDX8 or other sensor Removable terminals Cycle before dangerous failure: | B10d = 2,000,000 at 2A Risk duration 10 ms max Cable severing protection yes (opening of safety lines) Short-circuit protection and overload protection yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts 2 x NO 8A/250V + 2 x NF 8A/250V Diagnostics 1x NO 400mA/60V max Indicators 3 LEDs Reset automatic Mounting symmetrical DIN 35mm rail on DIN 50022 Mounting IP 54 electrical box Electrical connection Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature -25°C to +70°C. |
ECCN: | |
País de origen: | |
EAN: | |
Peso: | 0,00 kg |
Longitud: | 0,00 m |
Anchura: | 0,00 m |