315318
HiC2441
SMART Universal Barrier
1-channel isolated barrier, 24 V DC supply (bus powered), Analog input, digital input,, analog output, digital output, No configuration required, device is self-adapting, HART transparency, Low power dissipation, 3-way isolation, Up to SIL 2 acc. to IEC 61508pa. This isolated barrier is used for intrinsic safety applications. The device can transfer the following signals:, as an analog input: 0/4 mA .. 20 mA, as an analog output: 0/4 mA .. 20 mA, as a digital input: signals from NAMUR sensors or, dry contacts, as a digital output: max. 45 mA. The device requires no configuration and adapts itself automatically to the function of the active input/output of the connected process control system. The device permits the bi-directional pass-through of the HART communication. The device is designed primarily for use with universal I/O cards (e. g. Honeywell Universal Process IO). This device mounts on a HiC Termination Board.
Signal type: | Universal |
Safety Integrity Level (SIL): | SIL 2 |
Connection: | SL1: 1a(-), 1b(-); 2a(+), 2b(+) |
Rated voltage: | 19 ... 30 V DC via Termination Board |
Ripple: | ≤ 10 % |
Rated current: | ≤ 30 mA |
Power consumption: | ≤ 700 mW |
Suitable field devices: | 2-wire SMART transmitters, current sources |
Signal: | 0/4 ... 20 mA , limited to approx. 40 mA (depends on control system) , reverse polarity protected |
Field circuit: | SL2: 5a(+), 5b(-) (2-wire SMART transmitter) SL2: 5a(+), 1b(-) (2-wire SMART transmitter with current source) |
Voltage drop: | approx. 4 V (current source) |
Control circuit: | SL1: 8a(+), 7a(-) |
Supply voltage: | min. 16 V at 20 mA (2-wire SMART transmitter) |
Voltage: | 15 ... 30 V |
Signal: | 0/4 ... 20 mA , sink mode , working voltage 15 ... 30 V |
Ripple: | 20 mV rms |
Suitable field devices: | I/P converters (positioner), on-site-displays |
Signal: | 0/4 ... 20 mA |
Field circuit: | SL2: 5a(+), 5b(-) |
Load: | 0 ... 650 Ω |
Voltage: | ≥ 13 V at 20 mA |
Ripple: | 20 mV rms |
Control circuit: | SL1: 8a(+), 7a(-) |
Voltage: | 12 ... 30 V |
Signal: | 0/4 ... 20 mA |
Line fault detection: | > 100 kΩ at max. 30 V, with field wiring open |
Field circuit: | SL2: 5a(+), 1a(-) (NAMUR sensor) SL2: 5a(+), 5b(-) (dry contact) |
Suitable field devices: | NAMUR sensors according to IEC/EN 60947-5-6, dry contacts |
Signal: | 0.1 ... 9 mA , sink mode |
Open loop voltage: | approx. 10 V DC , 1 kΩ series resistance |
Signal: | 0.1 ... 9 mA |
Control circuit: | SL1: 8a(+), 7a(-) |
Voltage: | 13 ... 30 V |
Field circuit: | SL2: 5a(+), 5b(-) |
Suitable field devices: | solenoid valves, acoustic or visual alarms |
Drive capability: | 12 V / 40 mA at 300 Ω load |
Open loop voltage: | approx. 22 V |
Current limit: | 45 mA |
Internal resistor: | min. 240 Ω |
Control circuit: | SL1: 8a(+), 7a(-) |
Voltage: | 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC |
Current: | 1-signal: 0 ... 45 mA, depending on the output load 0-signal: < 0.1 mA, independent of the output load |
Power dissipation: | 1.1 W at 24 V, 300 Ω load (digital output) |
Deviation: | at 20 °C (68 °F) ≤ ±20 µA incl. linearity, hysteresis and supply fluctuations at 4 ... 20 mA (analog input, analog output) ≤ ±60 µA incl. linearity, hysteresis and supply fluctuations at 0 ... 45 mA (digital output) |
: Influence of ambient temperature: | < 2 µA/K (0 ... 70 °C (32 ... 158 °F)) < 3 µA/K (-40 ... 0 °C (-40 ... 32 °F)) |
Switching frequency: | ≤ 500 Hz with 50 % duty cycle (digital input, NAMUR sensor) ≤ 5 Hz (digital input, dry contact) ≤ 20 Hz (digital output) |
Frequency range: | HART: bandwidth by 0.5 Vpp signal and/or 1 mApp signal 950 ... 2500 Hz (analog input, analog output) |
Settling time: | ≤ 20 ms (analog input, analog output) ≤ 1 ms (digital input, NAMUR sensor) |
Reaction time: | ≤ 5 ms , turn-on/turn-off time (digital output) |
Control/power supply: | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1:2013 (industrial locations) |
Electromagnetic compatibility: | NE 21:2011 |
Degree of protection: | IEC 60529:2001 |
Protection against electrical shock: | IEC 61010-1:2010 |
Input: | EN 60947-5-6:2000 |
Ambient temperature: | -40 ... 70 °C (-40 ... 158 °F) Observe the temperature range limited by derating, see section derating. |
Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity: | 95 % non-condensing |
Degree of protection: | IP20 |
Mass: | approx. 100 g |
Dimensions: | 12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch) |
Mounting: | on Termination Board |
Coding: | pin 1 and 4 trimmed For further information see system description. |
EU-Type Examination Certificate: | TÜV 14 ATEX 153522 X |
Electromagnetic compatibility: Marking: | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I |
Supply: Maximum safe voltage: | 250 V (Attention! The rated voltage can be lower.) |
Equipment: | SL2: 5a(+), 5b(-) |
Supply: Voltage Uo: | 25.2 V |
Supply: Current Io: | 110 mA |
Supply: Power Po: | 693 mW |
Equipment: | SL2: 5a(+), 1b(-) |
Supply: Voltage Ui: | < 28 V |
Supply: Current Ii: | < 115 mA |
Supply: Voltage Uo: | 7.2 V |
Supply: Current Io: | 0 mA |
Supply: Power Po: | 0 mW |
Equipment: | SL2: 5a(+), 1a(-) |
Supply: Voltage Uo: | 12.6 V |
Supply: Current Io: | 13 mA |
Supply: Power Po: | 41 mW |
Certificate: | TÜV 14 ATEX 153523 X |
Supply: Marking: | II 3G Ex ec IIC T4 Gc |
Galvanic isolation: Input/Other circuits: | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-7:2015 |
UL approval: | E106378 |
Directive conformity: Control drawing: | 116-0408 (cULus) |
IECEx approval: IECEx certificate: | IECEx TUN 15.0004X |
IECEx approval: IECEx marking: | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
Supplementary information: | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
ТН ВЭД: | |
Страна происхождения: | SG |
EAN: | |
Вес: | 0,00 kg |
Длина: | 0,00 m |
Ширина: | 0,00 m |
Высота: | 0,00 m |