310665
NBB2-12GM60-E2-V1-M-Y310665
Inductive sensor
Series: Cylindrical type, Housing material: brass, nickel-plated, Output type: 3-wire, Installation: flush, Type of voltage: DC, Connection type: Connector M12 x 1 , 4-pin, Degree of protection: IP68fa
Switching function: | Normally open (NO) |
Output type: | PNP |
Rated operating distance: | 2 mm |
Installation: | flush |
Output polarity: | DC |
Assured operating distance: | 0 ... 1.62 mm |
Actuating element: | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
Reduction factor rAl: | 0.35 |
Reduction factor rCu: | 0.2 |
Reduction factor r304: | 0.7 |
Reduction factor rBrass: | 0.4 |
Output type: | 3-wire |
Installation conditions: A: | 0 mm |
Installation conditions: B: | 0 mm |
Installation conditions: C: | 6 mm |
Installation conditions: F: | 12 mm |
Operating voltage: | 10 ... 65 V |
Switching frequency: | 0 ... 1200 Hz |
Hysteresis: | 0.02 ... 0.44 |
Reverse polarity protection: | yes |
Short-circuit protection: | yes |
Overload resistance: | yes |
Wire breakage protection: | yes |
Inductive overvoltage protection: | yes |
Surge suppression: | yes |
Ripple: | 10 % |
Voltage drop: | ≤ 2.5 V |
Repeat accuracy: | 0.1 mm |
Operating current: | 0 ... 300 mA |
Off-state current: | 0.01 mA |
No-load supply current: | ≤ 10 mA |
Switching state indicator: | Multihole-LED, yellow |
MTTFd: | 1640 a |
Mission Time (TM): | 20 a |
Diagnostic Coverage (DC): | 0 % |
UL approval: | cULus Listed, General Purpose, Class 2 Power Source |
E1 Type approval: | 10R-04 |
Ambient temperature: | -40 ... 85 °C (-40 ... 185 °F) |
Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
Connection type: | Connector M12 x 1 , 4-pin |
Housing material: | brass, nickel-plated |
Sensing face: | PPS |
Degree of protection: | IP68 |
Mass: | 20 g |
ТН ВЭД: | |
Страна происхождения: | CZ |
EAN: | |
Вес: | 0,00 kg |
Длина: | 0,00 m |
Ширина: | 0,00 m |
Высота: | 0,00 m |