286519
LB8122A.1.EL
Gateway for PROFINET
The PROFINET gateway is the interface between the I/O modules on the backplane and the control system. Interface between the I/O modules and the PCS/PLC, Mounting in Zone 2, Class I/Div.2 or in the safe area, Non-volatile memory for configuration and parameter settings, Communication via PROFINETpa. HART communication is via PROFINET or HART I/P. In addition to the input/output data of the I/O modules, the HART auxiliary variables can also be accessed in the process image.
Connection: | backplane bus |
Rated voltage: | 12 V DC , only in connection with the power supplies LB9*** |
Nominal voltage: | 12 V DC , |
Power dissipation: | 3.65 W |
Power consumption: | 3.65 W |
Fieldbus type: | PROFINET |
Connection type: | RJ-45 , via front connector |
Transfer rate: | 10BASE-T, 100BASE-TX 100 MBit/s |
Station connection: | directly to PCS or PLC or via hubs or switches |
Cable type: | SFTP in accordance with ISO/IEC 11801 for Cat 5e or better |
Bus length: | max. 100 m Per link |
Addressing: | DHCP, via controller (DCP) or fixed IP address |
Ethernet address: | IP V4 address (preset: DHCP on, changeable via display) |
Supported I/O modules: | LB1x01*…LB1x03*, LB1x08*, LB1x09*, LB2x01*…LB2x17*, LB3x01*…LB3x06*, LB4x01*, LB4x02*, LB4x04*…LB4x06*, LB5x01*, LB5x02*, LB5x04*…LB5x06*, LB6x01*, LB6x05*, LB6x06*, LB6x08*, LB6x10*…LB6x17* |
HART communication: | via PROFINET and HART I/P |
PROFINET conformance class: | CC B |
Connection: | backplane bus |
Ethernet/other circuits: | basic insulation according to IEC/EN 61010-1, rated insulation voltage 35 Veff or 50 V DC |
RS 485 interface/other circuits: | basic insulation according to IEC/EN 61010-1, rated insulation voltage 35 Veff or 50 V DC |
Insulation voltage: | 1500 V AC acc. to IEEE 802.3u |
Power supply, internal bus/other circuits: | basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V DC |
Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1 |
Degree of protection: | IEC 60529 |
Fieldbus standard: | IEEE 802.3 |
Environmental test: | EN 60068-2-14 |
Shock resistance: | EN 60068-2-27 |
Vibration resistance: | EN 60068-2-6 |
Damaging gas: | EN 60068-2-42 |
Relative humidity: | EN 60068-2-56 |
Ambient temperature: | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature: | -25 ... 85 °C (-13 ... 185 °F) |
Relative humidity: | 95 % non-condensing |
Shock resistance: | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Vibration resistance: | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
Damaging gas: | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Degree of protection: | IP20 (module) , mounted on backplane |
Connection: | via backplane |
Mass: | approx. 150 g |
Dimensions: | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
Certificate: | DEMKO 16 ATEX 1780 X |
Electromagnetic compatibility: Marking: | II 3 G Ex nA IIC T4 Gc |
Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012+A11:2013 EN 60079-15:2010 |
ATEX approval: | DEMKO 16 ATEX 1780 X |
IECEx approval: | IECEx UL 16.0141 X |
Directive conformity: Approved for: | Ex nA IIC T4 Gc |
System information: | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. |
Supplementary information: | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |