Pepperl+Fuchs 264991

VAA-2E1A-G10-SAJ/EA2J-2M-V1-G

AS-Interface Sicherheitsmodul VAA-2E1A-G10-SAJ/EA2J-2M-V1-G

По запросу. Пожалуйста, отправьте нам письмо, чтобы узнать цену и наличие.
"ucnguBrctvdgcxgt0eqo"

Описание

The VAA-2E1A-G10-SAJ-*M-V1-G is an AS-Interface safety module with 2 safety-related inputs and one conventional output. A two-channel mechanical switch or a single channel mechanical switch each can be connected to the two safety-related inputs. The output is a conventional electronic non-safety-related output, which can be loaded with 50 mA. The module is suitable for remote connection of switches in very limited space. The onepiece housing provides a degree of protection of IP67 . The connection to the AS-Interface cable is achieved by means of insulation piercing method of the inserted flat cables. The inputs and the output are connected via an 8-pin M12 socket. To display the current switching state, there is a LED for each channel mounted on top of the module. A LED indicating the AS-Interface communication and the adress 0 of the module is also available. If a communication error occurs, the outputs are switched off (only at P0 = 1). The module can be used up to Category 4/PL e according to ISO 13849-1, SIL 3 according to EN 62061. If two single-channel switches are connected, the module can be used up to Category 2/ PL c according to ISO 13849-1, SIL 1 according to EN 62061.

Технические характеристики

Slave type: Safety-Slave
AS-Interface specification: V3.0
Required master specification: ≥ V2.1
UL File Number: E223772 "For use in NFPA 79 Applications only"
LED FLT: error display; LED red red: communication error or address is 0
LED AS-i: AS-Interface voltage; green LED green: voltage OK flashing green: address 0
LED IN: switching state (input); 2 LED yellow
LED OUT: Switching state (output); LED yellow
Rated operating voltage: 26.5 ... 31.6 V from AS-Interface (PELV)
Rated operating current: ≤ 90 mA
Protection class: III
Surge protection: overvoltage category III
Rated insulation voltage: 32 V
Pulse withstand voltage: 0.8 kV
Number/Type: 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or 1 2-channel contact: up to category 4/PL e to ISO 13849-1
Supply: from AS-Interface
Voltage: 20 ... 30 V DC pulsed
Current: input current limited ≤ 15 mA, short-circuit protected
Number/Type: 1 conventional electronic output, PNP
Supply: from AS-Interface
Voltage: (UASI - 7.0 V) ≤ UOUT ≤ UASI
Current: 50 mA , short-circuit/overload protected
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007
Machinery Directive: Directive 2006/42/EC: EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Degree of protection: EN 60529:2000
Fieldbus standard: EN 62026-2:2013
Electrical safety: IEC 61140:2009
Emitted interference: EN 61000-6-4:2007
AS-Interface: EN 62026-2:2013
Noise immunity: IEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005
Functional safety: EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Profile: S-7.B
IO code: 7
ID code: B
ID1 code: F
ID2 code: 0
Data bits (function via AS-Interface): input output
Machinery Directive: D0: dyn. safety code 1 OUT 1
Machinery Directive: D1: dyn. safety code 1 -
Machinery Directive: D2: dyn. safety code 2 -
Machinery Directive: D3: dyn. safety code 2 -
Parameter bits (programmable via AS-i): function
Machinery Directive: P0: communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
Machinery Directive: P1: not used
Machinery Directive: P2: not used
Machinery Directive: P3: not used
UL approval: cULus Listed, Type 1 enclosure
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -25 ... 80 °C (-13 ... 176 °F)
Relative humidity: < 95 %
Altitude: ≤ 2000 m above MSL
Shock and impact resistance: 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance: 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree: 3
Contact elements: spring-loaded contact socket
Degree of protection: IP67 This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE
Connection: AS-Interface: AS-Interface flat cable Inputs/outputs: M12 x 1 socket, 8-pin
Material: Contacts: CuSn / Au
Material: Contact surface: Au
Material: Housing: PBT
Material: Body: TPU, black
Material: Cable: PUR
Material: Slotted nut: Diecast zinc
Material: Mounting screw: Stainless steel 1.4305 / AISI 303
Cable: Sheath diameter: ∅4.8 mm
Cable: Bending radius: > 8 x cable diameter, fixed > 10 x cable diameter, moving not appropriate for conveyor chains
Cable: Color: black
Cable: Cores: 6 x 0.25 mm2
Cable: Length: 2 m
Mass: 200 g
Tightening torque, fastening screws: 1.65 Nm
Tightening torque, cable gland: 0.4 Nm

Логистические характеристики

ТН ВЭД:
Страна происхождения: SG
EAN:
Вес: 0,00 kg
Длина: 0,00 m
Ширина: 0,00 m
Высота: 0,00 m