50130471
HT49CI.UCH/TS-TB
HT49CI.UCH/TS-TB - Diffuse sensor with background suppression
| Series: | 49C |
| Operating principle: | Diffuse reflection principle with background suppression |
| Special version: | Heating |
| Black-white error: | < 10% up to 1200 mm |
| Operating range, white 90%: | 0.005 ... 3 m |
| Operating range, gray 18%: | 0.02 ... 2 m |
| Operating range, black 6%: | 0.05 ... 1.5 m |
| Operating range limit, white 90%: | 0.005 ... 3 m |
| Adjustment range: | 120 ... 3,000 mm |
| Light source: | LED, Infrared |
| Protective circuit: | Interference blanking, Transient protection |
| Supply voltage UB: | 20 ... 250 V, AC/DC |
| Power consumption (with AC): | 1.5 V·A |
| Number of digital switching outputs: | 2 Piece(s) |
| Switching element: | Relay, NC |
| Switching principle: | Light/dark reversible |
| Switching element: | Relay, NO |
| Switching principle: | Light/dark reversible |
| Switching frequency: | 25 Hz |
| Response time: | 20 ms |
| Function: | Signal OUT, Voltage supply |
| Type of connection: | Terminal |
| No. of pins: | 5 -pin |
| Dimension (W x H x L): | 31 mm x 104 mm x 55.5 mm |
| Housing material: | Plastic, PC |
| Lens cover material: | Plastic |
| Net weight: | 150 g |
| Type of fastening: | Via optional mounting device, Through-hole mounting |
| Operational controls: | Multiturn potentiometer, Teach button |
| Ambient temperature, operation: | -40 ... 60 °C |
| Degree of protection: | IP 67 |
| Protection class: | II |
| Certifications: | c UL US |
| Standards applied: | IEC 60947-5-2 |
| Customs tariff number: | 85365080 |
| eCl@ss 8.0: | 27270904 |
| eCl@ss 9.0: | 27270904 |
| ETIM 5.0: | EC002719 |
| ETIM 6.0: | EC002719 |
| ТН ВЭД: | |
| Страна происхождения: | Deutschland |
| EAN: | |
| Вес: | 0,17 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |