8972270000
VSPC CONTROL UNIT 24VDC
| Type: | VSPC CONTROL UNIT 24VDC |
| Order No.: | 8972270000 |
| Version: | Surge protection for instrumentation and control, 24 V, 50 mA, DIN EN 50178 |
| GTIN (EAN): | 4032248793488 |
| Qty.: | 1 pc(s). |
| Width: | 18 mm |
| Width (inches): | 0.709 inch |
| Height: | 102 mm |
| Height (inches): | 4.016 inch |
| Depth: | 71.5 mm |
| Depth (inches): | 2.815 inch |
| Net weight: | 73.57 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 50 mA |
| Input voltage, max. Ui: | 31 V |
| Internal capacity, max. CI: | 100 μF |
| Internal inductance, max. LI: | 300 μH |
| Colour: | orange |
| Design: | Installation housing |
| Protection degree: | IP20 |
| Rail: | TS 35, TS 35 x 7.5 |
| Segment: | Measurement - Monitoring - Setting |
| Start-up time after fault correction: | 60 s |
| Version: | with warning function / function indicator |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 24 V |
| Max. continuous voltage, Uc (DC): | 30 V |
| Standards: | DIN EN 50178 |
| Number of poles: | 1 |
| Operating current, Imax.: | 50 mA |
| Operating voltage: | 24 V |
| Rated current IN: | 50 mA |
| Signalling contact: | No |
| Start-up time after fault correction: | 60 s |
| Operating status: | LED green |
| Status indication: | Green LED |
| Wire break detection: | Red/green LED, flashing |
| Type: | 1 CO contact |
| Switching current: | 1 A |
| Switching voltage: | 250 V AC |
| Type of connection: | Pluggable screw connection |
| Stripping length, rated connection: | 5 mm |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.5 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross section, finely stranded, max.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 2.5 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 1.5 mm² |
| Long specification: | Evaluating unit for up to 10 VSPC R protected plugs. With voltage-free signalling contact and power supply. This can be wired with up to 10 base modules with optional remote monitoring and delivers the supply voltage. In case of protection module failure the voltage free signalling contact is triggered. |
| Short specification: | Evaluating unit for up to 10 VSPC BASE R protected plugs. With voltage-free signalling contact and power supply. |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSPC CONTROL UNIT 24VDC |
| Order No.: | 8972270000 |
| Version: | Surge protection for instrumentation and control, 24 V, 50 mA, DIN EN 50178 |
| GTIN (EAN): | 4032248793488 |
| Qty.: | 1 pc(s). |
| Width: | 18 mm |
| Width (inches): | 0.709 inch |
| Height: | 102 mm |
| Height (inches): | 4.016 inch |
| Depth: | 71.5 mm |
| Depth (inches): | 2.815 inch |
| Net weight: | 73.57 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 50 mA |
| Input voltage, max. Ui: | 31 V |
| Internal capacity, max. CI: | 100 μF |
| Internal inductance, max. LI: | 300 μH |
| Colour: | orange |
| Design: | Installation housing |
| Protection degree: | IP20 |
| Rail: | TS 35, TS 35 x 7.5 |
| Segment: | Measurement - Monitoring - Setting |
| Start-up time after fault correction: | 60 s |
| Version: | with warning function / function indicator |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 24 V |
| Max. continuous voltage, Uc (DC): | 30 V |
| Standards: | DIN EN 50178 |
| Number of poles: | 1 |
| Operating current, Imax.: | 50 mA |
| Operating voltage: | 24 V |
| Rated current IN: | 50 mA |
| Signalling contact: | No |
| Start-up time after fault correction: | 60 s |
| Operating status: | LED green |
| Status indication: | Green LED |
| Wire break detection: | Red/green LED, flashing |
| Type: | 1 CO contact |
| Switching current: | 1 A |
| Switching voltage: | 250 V AC |
| Type of connection: | Pluggable screw connection |
| Stripping length, rated connection: | 5 mm |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.5 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross section, finely stranded, max.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 2.5 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 1.5 mm² |
| Long specification: | Evaluating unit for up to 10 VSPC R protected plugs. With voltage-free signalling contact and power supply. This can be wired with up to 10 base modules with optional remote monitoring and delivers the supply voltage. In case of protection module failure the voltage free signalling contact is triggered. |
| Short specification: | Evaluating unit for up to 10 VSPC BASE R protected plugs. With voltage-free signalling contact and power supply. |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,092 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |