8951760000
VSPC BASE 4SL FG R
| Type: | VSPC BASE 4SL FG R |
| Order No.: | 8951760000 |
| Version: | Surge protection, Flange-mounted housing, 300 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248743001 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 98 mm |
| Height (inches): | 3.858 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 76 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Connection type: | Screw connection |
| Max. torque: | 0.2 Nm |
| Stripping length: | 6 mm |
| Cross-section for connected wire, solid core, min.: | 0.5 mm² |
| Cross-section for connected wire, solid core, max.: | 1.5 mm² |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 350 mA |
| Internal inductance, max. LI: | 0 µH |
| Colour: | black |
| Design: | Terminal, miscellaneous |
| Optical function display: | No |
| Protection degree: | IP20 |
| Rail: | TS 35, TS 35 x 7.5 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | Flange-mounted housing |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Voltage type: | AC/DC |
| Standards: | IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Leakage current at Un: | 0 µA |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Rated current IN: | 300 mA |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 7 mm |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 4 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 2.5 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 2.5 mm² |
| Blade size: | 0.6 x 3.5 mm |
| Long specification: | Base element can take a protected plug for up to four floating-ground powered paired cables. When the base unit is fitted, a simultaneous sparkover gap to high impedance earth is made between the mounting rail (earth) and the reference potential (ground) of the protective switch in the plug. With optional remote monitoring. Mechanical coding of the base element to the protected plug according to switching type and rated voltage. The base unit is coded itself by the first insertion of a protected plug. Possible to mark all terminals |
| Short specification: | Base element receives a protected plug for up to four floating-ground powered paired cables with indirect earthing. With optional remote monitoring. |
| ETIM 6.0: | EC000472 |
| ETIM 7.0: | EC000472 |
| eClass 9.0: | 27-13-08-03 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-03 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSPC BASE 4SL FG R |
| Order No.: | 8951760000 |
| Version: | Surge protection, Flange-mounted housing, 300 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248743001 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 98 mm |
| Height (inches): | 3.858 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 76 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Connection type: | Screw connection |
| Max. torque: | 0.2 Nm |
| Stripping length: | 6 mm |
| Cross-section for connected wire, solid core, min.: | 0.5 mm² |
| Cross-section for connected wire, solid core, max.: | 1.5 mm² |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 350 mA |
| Internal inductance, max. LI: | 0 µH |
| Colour: | black |
| Design: | Terminal, miscellaneous |
| Optical function display: | No |
| Protection degree: | IP20 |
| Rail: | TS 35, TS 35 x 7.5 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | Flange-mounted housing |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Voltage type: | AC/DC |
| Standards: | IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Leakage current at Un: | 0 µA |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Rated current IN: | 300 mA |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 7 mm |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 4 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 2.5 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 2.5 mm² |
| Blade size: | 0.6 x 3.5 mm |
| Long specification: | Base element can take a protected plug for up to four floating-ground powered paired cables. When the base unit is fitted, a simultaneous sparkover gap to high impedance earth is made between the mounting rail (earth) and the reference potential (ground) of the protective switch in the plug. With optional remote monitoring. Mechanical coding of the base element to the protected plug according to switching type and rated voltage. The base unit is coded itself by the first insertion of a protected plug. Possible to mark all terminals |
| Short specification: | Base element receives a protected plug for up to four floating-ground powered paired cables with indirect earthing. With optional remote monitoring. |
| ETIM 6.0: | EC000472 |
| ETIM 7.0: | EC000472 |
| eClass 9.0: | 27-13-08-03 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-03 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,078 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |