Type: VSPC RS485 2CH
Order No.: 8924670000
Version: Surge protection for instrumentation and control, 5 V, 5 V, 450 mA, IEC 61643-21
GTIN (EAN): 4032248696314
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 27.5 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 57
MTTF: 2,003 Years
PFH in 1*10-9 per hour: 4.25
SFF: 92.54 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input voltage, max. Ui: 6.4 V
Internal capacity, max. CI: 11 nF
Internal inductance, max. LI: 0 µH
Colour: orange
Design: Terminal, miscellaneous
Protection degree: IP20
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: without warning function / function indicator
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 5 V
Rated voltage (DC): 5 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 5 V
Max. continuous voltage, Uc (DC): 6.4 V
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 2 x 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current, Iimp (10/350 µs) GND-PE: 0.2 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 2 x 0.2 kA
Lightning test current, Iimp (10/350 µs) wire-wire: 0.2 kA
Standards: IEC 61643-21
Protection level UP (typ.): 250 V
Protection level on output side Wire-PE 1kV/µs, typically: 10 V
Protection level on output side Wire-wire 1 kV/µs, typically: 10 V
Protection level on output side Wire-wire 8/20 µs, typically: 15 V
Protection level, UP GND - PE: 500 V
Protection level, UP wire - PE: 35 V
Insertion loss: 113.7 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 15 V
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 450 mA
Requirements category acc. to IEC 61643-21: C1, C2, C3, D1
Signal transmission properties (-3 dB): 113.6 MHz
Signalling contact: No
Surge current-carrying capacity C1: < 1 kA 8/20 μs
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: 2.20 Ω
Type of connection: Pluggable in VSPC BASE
Long specification: Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven signal cables and ground, e.g. for bus systems. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and additional coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
Short specification: Surge protection plug for base element VSPC BASE 2CL, transverse voltage coarse and fine protection for two floating-ground powered IT signal cables, coarse common mode voltage protection to earth. Version: 5V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSPC RS485 2CH
Order No.: 8924670000
Version: Surge protection for instrumentation and control, 5 V, 5 V, 450 mA, IEC 61643-21
GTIN (EAN): 4032248696314
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 27.5 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 57
MTTF: 2,003 Years
PFH in 1*10-9 per hour: 4.25
SFF: 92.54 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input voltage, max. Ui: 6.4 V
Internal capacity, max. CI: 11 nF
Internal inductance, max. LI: 0 µH
Colour: orange
Design: Terminal, miscellaneous
Protection degree: IP20
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: without warning function / function indicator
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 5 V
Rated voltage (DC): 5 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 5 V
Max. continuous voltage, Uc (DC): 6.4 V
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 2 x 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current, Iimp (10/350 µs) GND-PE: 0.2 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 2 x 0.2 kA
Lightning test current, Iimp (10/350 µs) wire-wire: 0.2 kA
Standards: IEC 61643-21
Protection level UP (typ.): 250 V
Protection level on output side Wire-PE 1kV/µs, typically: 10 V
Protection level on output side Wire-wire 1 kV/µs, typically: 10 V
Protection level on output side Wire-wire 8/20 µs, typically: 15 V
Protection level, UP GND - PE: 500 V
Protection level, UP wire - PE: 35 V
Insertion loss: 113.7 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 15 V
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 450 mA
Requirements category acc. to IEC 61643-21: C1, C2, C3, D1
Signal transmission properties (-3 dB): 113.6 MHz
Signalling contact: No
Surge current-carrying capacity C1: < 1 kA 8/20 μs
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: 2.20 Ω
Type of connection: Pluggable in VSPC BASE
Long specification: Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven signal cables and ground, e.g. for bus systems. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and additional coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
Short specification: Surge protection plug for base element VSPC BASE 2CL, transverse voltage coarse and fine protection for two floating-ground powered IT signal cables, coarse common mode voltage protection to earth. Version: 5V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,047 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m