Article image 8823280000

Weidmueller 8823280000

MCZ OVP SL FG 24VUC 0,5A

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: MCZ OVP SL FG 24VUC 0,5A
Order No.: 8823280000
Version: MCZ SERIES, Surge protection for instrumentation and control, 0.5 A
GTIN (EAN): 4032248524358
Qty.: 10 pc(s).
Width: 6 mm
Width (inches): 0.236 inch
Height: 91 mm
Height (inches): 3.583 inch
Depth: 63.5 mm
Depth (inches): 2.5 inch
Net weight: 27.2 g
Operating temperature, max.: 60 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Colour: black
Design: Terminal
Height with TS 35: 63.5 mm
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 24 V
Rated voltage (DC), max.: 38 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 28 V
Discharge current, max. (8/20 µs): 5 kA
Discharge current, Iimp (10/350 µs): 1 kA
Lightning test current Iimp (10/350 µs): 1 kA
Fuse: 0.5 A
Protection level on output side Wire-PE 1kV/µs, typically: 40 V
Protection level on output side Wire-PE 8/20 µs, typically: 65 V
Protection level on output side Wire-wire 1 kV/µs, typically: 40 V
Protection level on output side Wire-wire 8/20 µs, typically: 65 V
Dielectric strength at FG against PE: ≥ 500 V
Inductance L and L1: 35 µH
Limiting frequency (-3 dB) at load resistance: 500 kHz 240 Ω
Load resistance (for limiting frequency): 240 Ω
Operating current, Imax.: 0.5 A
Operating voltage: 38 V
Rated current IN: 0.5 A
Requirements category acc. to IEC 61643-21: D1
Response time: ≤ 100 ps
Volume resistance: 1.00 Ω
Cross-section: 1.5 mm²
Wire connection method: Spring connection
Type of connection: Tension-clamp connection
Stripping length, rated connection: 8 mm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 1.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 16
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 1.5 mm²
Wire connection cross-section, finely stranded, min.: 0.5 mm²
Wire connection cross section, finely stranded, max.: 1.5 mm²
Wire cross-section, finely stranded, min. (AWG): AWG 26
Wire cross-section, finely stranded, max. (AWG): AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 1.5 mm²
Blade size: 0.6 x 3.5 mm
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform
Type: MCZ OVP SL FG 24VUC 0,5A
Order No.: 8823280000
Version: MCZ SERIES, Surge protection for instrumentation and control, 0.5 A
GTIN (EAN): 4032248524358
Qty.: 10 pc(s).
Width: 6 mm
Width (inches): 0.236 inch
Height: 91 mm
Height (inches): 3.583 inch
Depth: 63.5 mm
Depth (inches): 2.5 inch
Net weight: 27.2 g
Operating temperature, max.: 60 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Colour: black
Design: Terminal
Height with TS 35: 63.5 mm
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 24 V
Rated voltage (DC), max.: 38 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 28 V
Discharge current, max. (8/20 µs): 5 kA
Discharge current, Iimp (10/350 µs): 1 kA
Lightning test current Iimp (10/350 µs): 1 kA
Fuse: 0.5 A
Protection level on output side Wire-PE 1kV/µs, typically: 40 V
Protection level on output side Wire-PE 8/20 µs, typically: 65 V
Protection level on output side Wire-wire 1 kV/µs, typically: 40 V
Protection level on output side Wire-wire 8/20 µs, typically: 65 V
Dielectric strength at FG against PE: ≥ 500 V
Inductance L and L1: 35 µH
Limiting frequency (-3 dB) at load resistance: 500 kHz 240 Ω
Load resistance (for limiting frequency): 240 Ω
Operating current, Imax.: 0.5 A
Operating voltage: 38 V
Rated current IN: 0.5 A
Requirements category acc. to IEC 61643-21: D1
Response time: ≤ 100 ps
Volume resistance: 1.00 Ω
Cross-section: 1.5 mm²
Wire connection method: Spring connection
Type of connection: Tension-clamp connection
Stripping length, rated connection: 8 mm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 1.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 16
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 1.5 mm²
Wire connection cross-section, finely stranded, min.: 0.5 mm²
Wire connection cross section, finely stranded, max.: 1.5 mm²
Wire cross-section, finely stranded, min. (AWG): AWG 26
Wire cross-section, finely stranded, max. (AWG): AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 1.5 mm²
Blade size: 0.6 x 3.5 mm
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,027 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m