Article image 7760054164

Weidmueller 7760054164

ACT20P-VMR-1PH-H-S

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: ACT20P-VMR-1PH-H-S
Order No.: 7760054164
Version: Limit value monitoring, Input: single-phase voltage, Relay output
GTIN (EAN): 6944169689079
Qty.: 1 pc(s).
Width: 22.5
Width (inches): 0.886 inch
Height: 117 mm
Height (inches): 4.606 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 198.7 g
Humidity: 5...85 % rel. humidity, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E469563
Number of inputs: 1
Type: single-phase
Input voltage: Channel 1: (U1-E): 110V AC/DC, Channel 2: (U2-E): 240V AC/DC, Channel 3 1: (U3-E): 400V AC/DC
Input resistance, voltage: 1 MΩ±5%
Input frequency: 40…60 Hz, DC
Configuration: DIP switch and potentiometer
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Power consumption: ≤ 100 mA @ 24 VDC, ≤ 120mA @ 24V AC
Rail: TS 35
Step response time: < 220 ms (10...90 %)
Temperature coefficient: 350 ppm/K
Voltage supply: 24…240 VUC ±10%
EMC standards: IEC 61326-1
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage: Supply⁄output: 4 kV; input/output, input/output: 6 kV, 1.2/50 µs
Insulation voltage: 2.5 kV (input / output), 2 kV input / output/ power supply
Pollution severity: 2
Rated voltage: 300 VAC (output 1 - output 2), 300 VAC (supply-output), 500 VAC (supply-input; input-output)
Surge voltage category: III
Alarm function: Top and bottom limit values, window range, Holding function can be activated, Alarm delay: 0…10 s
Hysteresis: 5% of final value
Number of digital outputs: 2
Type: 2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted
Max. switching voltage, DC: 30 V
Max. switching voltage, AC: 250 V
Rated switching current: 5 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002654
ETIM 7.0: EC002654
eClass 9.0: 27-21-01-22
eClass 9.1: 27-21-01-22
eClass 10.0: 27-21-01-22
ROHS: Conform
Type: ACT20P-VMR-1PH-H-S
Order No.: 7760054164
Version: Limit value monitoring, Input: single-phase voltage, Relay output
GTIN (EAN): 6944169689079
Qty.: 1 pc(s).
Width: 22.5
Width (inches): 0.886 inch
Height: 117 mm
Height (inches): 4.606 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 198.7 g
Humidity: 5...85 % rel. humidity, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E469563
Number of inputs: 1
Type: single-phase
Input voltage: Channel 1: (U1-E): 110V AC/DC, Channel 2: (U2-E): 240V AC/DC, Channel 3 1: (U3-E): 400V AC/DC
Input resistance, voltage: 1 MΩ±5%
Input frequency: 40…60 Hz, DC
Configuration: DIP switch and potentiometer
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Power consumption: ≤ 100 mA @ 24 VDC, ≤ 120mA @ 24V AC
Rail: TS 35
Step response time: < 220 ms (10...90 %)
Temperature coefficient: 350 ppm/K
Voltage supply: 24…240 VUC ±10%
EMC standards: IEC 61326-1
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage: Supply⁄output: 4 kV; input/output, input/output: 6 kV, 1.2/50 µs
Insulation voltage: 2.5 kV (input / output), 2 kV input / output/ power supply
Pollution severity: 2
Rated voltage: 300 VAC (output 1 - output 2), 300 VAC (supply-output), 500 VAC (supply-input; input-output)
Surge voltage category: III
Alarm function: Top and bottom limit values, window range, Holding function can be activated, Alarm delay: 0…10 s
Hysteresis: 5% of final value
Number of digital outputs: 2
Type: 2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted
Max. switching voltage, DC: 30 V
Max. switching voltage, AC: 250 V
Rated switching current: 5 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002654
ETIM 7.0: EC002654
eClass 9.0: 27-21-01-22
eClass 9.1: 27-21-01-22
eClass 10.0: 27-21-01-22
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,23 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m