Article image 2501110000

Weidmueller 2501110000

PICOPAK-CI-CO-LP-P

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: PICOPAK-CI-CO-LP-P
Order No.: 2501110000
Version: Signal converter/insulator, Output current loop powered, Input : 4-20 mA, Output : 4-20 mA
GTIN (EAN): 4050118514704
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 79.4 mm
Height (inches): 3.126 inch
Depth: 55 mm
Depth (inches): 2.165 inch
Weight: 50 g
Net weight: 47 g
Humidity: 0...95 % (no condensation)
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...85 °C
Certificate No. (cURus): E141197
Number of inputs: 1
Sensor: Current source
Input current: 4...20 mA
Voltage drop, current input: ≤3,5 V
Number of outputs: 1
Output current: 4...20 mA, loop-powered
Cut-off frequency (-3 dB): ≥3,5 kHz
Load impedance current: ≤ 600 Ω
Supply voltage (output): 18…32 V
Accuracy: < 0.1 % of measuring range
Configuration: Potentiometer
Galvanic isolation: 2-way isolator
Long-term drift: ≤±0.05% of the measurement range / year
Power consumption, max.: 0.85 W
Power consumption, typ.: 0.55 W
Rail: TS 35
Standard: EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Step response time: ≤ 5 ms
Temperature coefficient: ≤ 200 ppm/K
Voltage supply: Output loop powered
EMC standards: EN 61326-1
Galvanic isolation: 2-way isolator
Insulation voltage: 3.5 kV
Pollution severity: 2
Standard: EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Surge voltage category: II
Type of connection: PUSH IN
Wire connection cross-section, finely stranded, min.: 0.5 mm²
Wire connection cross section, finely stranded, max.: 1.5 mm²
Wire cross-section, finely stranded, min. (AWG): AWG 20
Wire cross-section, finely stranded, max. (AWG): AWG 14
Product information: The passive Isolator PicoPak-CI-CO-LP separates stand- analogue current signals. An analogue input current signal is converted linear and galvanic isolated into an analogue out- put current signal. The power supply occurs through the input and output measuring circuit. The measuring range can be adjusted if necessary via the potentiometers (Zero and Span) installed on the front.
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-90
eClass 10.0: 27-21-01-20
ROHS: Conform
Type: PICOPAK-CI-CO-LP-P
Order No.: 2501110000
Version: Signal converter/insulator, Output current loop powered, Input : 4-20 mA, Output : 4-20 mA
GTIN (EAN): 4050118514704
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 79.4 mm
Height (inches): 3.126 inch
Depth: 55 mm
Depth (inches): 2.165 inch
Weight: 50 g
Net weight: 47 g
Humidity: 0...95 % (no condensation)
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...85 °C
Certificate No. (cURus): E141197
Number of inputs: 1
Sensor: Current source
Input current: 4...20 mA
Voltage drop, current input: ≤3,5 V
Number of outputs: 1
Output current: 4...20 mA, loop-powered
Cut-off frequency (-3 dB): ≥3,5 kHz
Load impedance current: ≤ 600 Ω
Supply voltage (output): 18…32 V
Accuracy: < 0.1 % of measuring range
Configuration: Potentiometer
Galvanic isolation: 2-way isolator
Long-term drift: ≤±0.05% of the measurement range / year
Power consumption, max.: 0.85 W
Power consumption, typ.: 0.55 W
Rail: TS 35
Standard: EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Step response time: ≤ 5 ms
Temperature coefficient: ≤ 200 ppm/K
Voltage supply: Output loop powered
EMC standards: EN 61326-1
Galvanic isolation: 2-way isolator
Insulation voltage: 3.5 kV
Pollution severity: 2
Standard: EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Surge voltage category: II
Type of connection: PUSH IN
Wire connection cross-section, finely stranded, min.: 0.5 mm²
Wire connection cross section, finely stranded, max.: 1.5 mm²
Wire cross-section, finely stranded, min. (AWG): AWG 20
Wire cross-section, finely stranded, max. (AWG): AWG 14
Product information: The passive Isolator PicoPak-CI-CO-LP separates stand- analogue current signals. An analogue input current signal is converted linear and galvanic isolated into an analogue out- put current signal. The power supply occurs through the input and output measuring circuit. The measuring range can be adjusted if necessary via the potentiometers (Zero and Span) installed on the front.
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-90
eClass 10.0: 27-21-01-20
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,047 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m