2459940000
BLF 3.50/12/180LR SN BK BX
Type: | BLF 3.50/12/180LR SN BK BX |
Order No.: | 2459940000 |
Version: | PCB plug-in connector, female plug, 3.50 mm, Number of poles: 12, 180°, PUSH IN, Spring connection, Clamping range, max. : 1.5 mm², Box |
GTIN (EAN): | 4050118475357 |
Qty.: | 36 pc(s). |
Packaging: | Box |
Width: | 48.9 |
Width (inches): | 1.925 inch |
Height: | 15.08 mm |
Height (inches): | 0.594 inch |
Depth: | 30.05 mm |
Depth (inches): | 1.183 inch |
Net weight: | 9.258 g |
Product family: | OMNIMATE Signal - series BL/SL 3.50 |
Type of connection: | Field connection |
Wire connection method: | PUSH IN, Spring connection |
Pitch in mm (P): | 3.5 mm |
Pitch in inches (P): | 0.138 inch |
Conductor outlet direction: | 180° |
Number of poles: | 12 |
L1 in mm: | 38.5 mm |
L1 in inches: | 1.516 inch |
Number of rows: | 1 |
Pin series quantity: | 1 |
Rated cross-section: | 1.5 mm² |
Touch-safe protection acc. to DIN VDE 57 106: | Safe from finger touch |
Touch-safe protection acc. to DIN VDE 0470: | IP 20 |
Volume resistance: | ≤ 5mΩ |
Can be coded: | Yes |
Stripping length: | 8 mm |
min.: | 0 mm |
max.: | 1 mm |
Screwdriver blade: | 0.4 x 2.5 |
Screwdriver blade standard: | DIN 5264-A |
Plugging cycles: | 25 |
Plugging force/pole, max.: | 6 N |
Pulling force/pole, max.: | 6 N |
Insulating material: | PA GF |
Colour: | black |
Colour of operational elements: | orange |
Material of operational elements: | PA 66/6 |
Colour chart (similar): | RAL 9011 |
Insulating material group: | II |
Comparative Tracking Index (CTI): | ≥ 400, ≤ 600 |
UL 94 flammability rating: | V-0 |
GWFI: | 960 °C |
Contact material: | Copper alloy |
Contact surface: | tinned |
Storage temperature, min.: | -25 °C |
Storage temperature, max.: | 50 °C |
Max. relative humidity during storage: | 70 % |
Operating temperature, min.: | -50 °C |
Operating temperature, max.: | 120 °C |
Temperature range, installation, min.: | -30 °C |
Temperature range, installation, max.: | 100 °C |
Clamping range, min.: | 0.14 mm² |
Clamping range, max.: | 1.5 mm² |
Wire connection cross section AWG, min.: | AWG 26 |
Wire connection cross section AWG, max.: | AWG 16 |
Solid, min. H05(07) V-U: | 0.14 mm² |
Solid, max. H05(07) V-U: | 1.5 mm² |
Flexible, min. H05(07) V-K: | 0.14 mm² |
Flexible, max. H05(07) V-K: | 1.5 mm² |
w. plastic collar ferrule, DIN 46228 pt 4, min.: | 0.25 mm² |
w. plastic collar ferrule, DIN 46228 pt 4, max.: | 1 mm² |
w. wire end ferrule, DIN 46228 pt 1, min.: | 0.25 mm² |
w. wire end ferrule, DIN 46228 pt 1, max.: | 1 mm² |
Plug gauge in accordance with EN 60999 a x b; ø: | 2.4 mm x 1.5 mm |
Type: | fine-wired |
nominal: | 0.25 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 0.34 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 0.5 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 0.75 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 1 mm² |
nominal: | 10 mm |
Reference text: | The outside diameter of the plastic collar should not be larger than the pitch (P), Length of ferrules is to be chosen depending on the product and the rated voltage. |
Max. clamping range: | 1.5 mm² |
tested acc. to standard: | IEC 60664-1, IEC 61984 |
Rated current, min. number of poles (Tu=20°C): | 17.5 A |
Rated current, max. number of poles (Tu=20°C): | 14.7 A |
Rated current, min. number of poles (Tu=40°C): | 17.1 A |
Rated current, max. number of poles (Tu=40°C): | 13.1 A |
Rated voltage for surge voltage class / pollution degree II/2: | 320 V |
Rated voltage for surge voltage class / pollution degree III/2: | 160 V |
Rated voltage for surge voltage class / pollution degree III/3: | 160 V |
Rated impulse voltage for surge voltage class/ pollution degree II/2: | 2.5 kV |
Rated impulse voltage for surge voltage class/ pollution degree III/2: | 2.5 kV |
Rated impulse voltage for surge voltage class/ contamination degree III/3: | 2.5 kV |
Short-time withstand current resistance: | 1 x 1s with 120 A |
Rated voltage (Use group B / CSA): | 300 V |
Rated voltage (Use group C / CSA): | 50 V |
Rated voltage (Use group D / CSA): | 300 V |
Rated current (Use group B / CSA): | 10 A |
Rated current (Use group D / CSA): | 10 A |
Wire cross-section, AWG, min.: | AWG 26 |
Wire cross-section, AWG, max.: | AWG 16 |
Certificate No. (cURus): | E60693 |
Rated voltage (Use group B / UL 1059): | 300 V |
Rated voltage (Use group C / UL 1059): | 50 V |
Rated voltage (Use group D / UL 1059): | 300 V |
Rated current (Use group D / UL 1059): | 10 A |
Wire cross-section, AWG, min.: | AWG 26 |
Wire cross-section, AWG, max.: | AWG 16 |
Reference to approval values: | Specifications are maximum values, details - see approval certificate. |
Packaging: | Box |
VPE length: | 0 m |
VPE width: | 0 m |
VPE height: | 0 m |
Standard: | IEC 60512-1-1:2002-02 |
Test: | dimensional inspection |
Evaluation: | passed |
Standard: | IEC 60512-1-2:2002-02 |
Test: | weight check |
Evaluation: | passed |
Standard: | IEC 61984:2001-10 section 6.2 |
Test: | visual examination |
Evaluation: | passed |
Standard: | IEC 60068-2-70:1995-12 test Xb |
Test: | mark of origin, type identification, pitch, type of material, date clock, approval marking UL, approval marking CSA |
Evaluation: | available |
Test: | durability |
Evaluation: | passed |
Standard: | IEC 60512-13-5:2006-02 |
Test: | 180° turned with coding elements |
Evaluation: | passed |
Test: | 180° turned without coding elements |
Evaluation: | passed |
Test: | visual examination |
Evaluation: | passed |
Standard: | IEC 60999-1:1999-11 section 9.1, IEC 60947-1:2011-03 section 8.2.4.5.1 |
Type of conductor and conductor cross-section: | solid 0.14 mm² |
Type of conductor and conductor cross-section: | stranded 0.14 mm² |
Type of conductor and conductor cross-section: | solid 1.5 mm² |
Type of conductor and conductor cross-section: | stranded 1.5 mm² |
Type of conductor and conductor cross-section: | AWG 26/1 |
Type of conductor and conductor cross-section: | AWG 26/19 |
Type of conductor and conductor cross-section: | AWG 16/1 |
Type of conductor and conductor cross-section: | AWG 16/19 |
Evaluation: | passed |
Standard: | IEC 60999-1:1999-11 section 9.4 bzw. section 8.10 |
Requirement: | 0.2 kg |
Type of conductor and conductor cross-section: | AWG 26/1 |
Type of conductor and conductor cross-section: | AWG 26/19 |
Evaluation: | passed |
Requirement: | 0.3 kg |
Type of conductor and conductor cross-section: | H05V-U0.5 |
Type of conductor and conductor cross-section: | H05V-K0.5 |
Evaluation: | passed |
Requirement: | 0.4 kg |
Type of conductor and conductor cross-section: | H07V-U1.5 |
Type of conductor and conductor cross-section: | H07V-K1.5 |
Type of conductor and conductor cross-section: | AWG 16/1 |
Type of conductor and conductor cross-section: | AWG 16/19 |
Evaluation: | passed |
Standard: | IEC 60999-1:1999-11 section 9.5 |
Requirement: | ≥10 N |
Type of conductor and conductor cross-section: | AWG 26/1 |
Type of conductor and conductor cross-section: | AWG 26/19 |
Evaluation: | passed |
Requirement: | ≥20 N |
Type of conductor and conductor cross-section: | H05V-U0.5 |
Type of conductor and conductor cross-section: | H05V-K0.5 |
Evaluation: | passed |
Requirement: | ≥40 N |
Type of conductor and conductor cross-section: | H07V-U1.5 |
Type of conductor and conductor cross-section: | H07V-K1.5 |
Type of conductor and conductor cross-section: | AWG 16/1 |
Type of conductor and conductor cross-section: | AWG 16/19 |
Evaluation: | passed |
ETIM 6.0: | EC002638 |
ETIM 7.0: | EC002638 |
eClass 9.0: | 27-44-03-09 |
eClass 9.1: | 27-44-03-09 |
eClass 10.0: | 27-44-03-09 |
IPC conformity: | Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request. |
Type: | BLF 3.50/12/180LR SN BK BX |
Order No.: | 2459940000 |
Version: | PCB plug-in connector, female plug, 3.50 mm, Number of poles: 12, 180°, PUSH IN, Spring connection, Clamping range, max. : 1.5 mm², Box |
GTIN (EAN): | 4050118475357 |
Qty.: | 36 pc(s). |
Packaging: | Box |
Width: | 48.9 |
Width (inches): | 1.925 inch |
Height: | 15.08 mm |
Height (inches): | 0.594 inch |
Depth: | 30.05 mm |
Depth (inches): | 1.183 inch |
Net weight: | 9.258 g |
Product family: | OMNIMATE Signal - series BL/SL 3.50 |
Type of connection: | Field connection |
Wire connection method: | PUSH IN, Spring connection |
Pitch in mm (P): | 3.5 mm |
Pitch in inches (P): | 0.138 inch |
Conductor outlet direction: | 180° |
Number of poles: | 12 |
L1 in mm: | 38.5 mm |
L1 in inches: | 1.516 inch |
Number of rows: | 1 |
Pin series quantity: | 1 |
Rated cross-section: | 1.5 mm² |
Touch-safe protection acc. to DIN VDE 57 106: | Safe from finger touch |
Touch-safe protection acc. to DIN VDE 0470: | IP 20 |
Volume resistance: | ≤ 5mΩ |
Can be coded: | Yes |
Stripping length: | 8 mm |
min.: | 0 mm |
max.: | 1 mm |
Screwdriver blade: | 0.4 x 2.5 |
Screwdriver blade standard: | DIN 5264-A |
Plugging cycles: | 25 |
Plugging force/pole, max.: | 6 N |
Pulling force/pole, max.: | 6 N |
Insulating material: | PA GF |
Colour: | black |
Colour of operational elements: | orange |
Material of operational elements: | PA 66/6 |
Colour chart (similar): | RAL 9011 |
Insulating material group: | II |
Comparative Tracking Index (CTI): | ≥ 400, ≤ 600 |
UL 94 flammability rating: | V-0 |
GWFI: | 960 °C |
Contact material: | Copper alloy |
Contact surface: | tinned |
Storage temperature, min.: | -25 °C |
Storage temperature, max.: | 50 °C |
Max. relative humidity during storage: | 70 % |
Operating temperature, min.: | -50 °C |
Operating temperature, max.: | 120 °C |
Temperature range, installation, min.: | -30 °C |
Temperature range, installation, max.: | 100 °C |
Clamping range, min.: | 0.14 mm² |
Clamping range, max.: | 1.5 mm² |
Wire connection cross section AWG, min.: | AWG 26 |
Wire connection cross section AWG, max.: | AWG 16 |
Solid, min. H05(07) V-U: | 0.14 mm² |
Solid, max. H05(07) V-U: | 1.5 mm² |
Flexible, min. H05(07) V-K: | 0.14 mm² |
Flexible, max. H05(07) V-K: | 1.5 mm² |
w. plastic collar ferrule, DIN 46228 pt 4, min.: | 0.25 mm² |
w. plastic collar ferrule, DIN 46228 pt 4, max.: | 1 mm² |
w. wire end ferrule, DIN 46228 pt 1, min.: | 0.25 mm² |
w. wire end ferrule, DIN 46228 pt 1, max.: | 1 mm² |
Plug gauge in accordance with EN 60999 a x b; ø: | 2.4 mm x 1.5 mm |
Type: | fine-wired |
nominal: | 0.25 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 0.34 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 0.5 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 0.75 mm² |
nominal: | 10 mm |
Type: | fine-wired |
nominal: | 1 mm² |
nominal: | 10 mm |
Reference text: | The outside diameter of the plastic collar should not be larger than the pitch (P), Length of ferrules is to be chosen depending on the product and the rated voltage. |
Max. clamping range: | 1.5 mm² |
tested acc. to standard: | IEC 60664-1, IEC 61984 |
Rated current, min. number of poles (Tu=20°C): | 17.5 A |
Rated current, max. number of poles (Tu=20°C): | 14.7 A |
Rated current, min. number of poles (Tu=40°C): | 17.1 A |
Rated current, max. number of poles (Tu=40°C): | 13.1 A |
Rated voltage for surge voltage class / pollution degree II/2: | 320 V |
Rated voltage for surge voltage class / pollution degree III/2: | 160 V |
Rated voltage for surge voltage class / pollution degree III/3: | 160 V |
Rated impulse voltage for surge voltage class/ pollution degree II/2: | 2.5 kV |
Rated impulse voltage for surge voltage class/ pollution degree III/2: | 2.5 kV |
Rated impulse voltage for surge voltage class/ contamination degree III/3: | 2.5 kV |
Short-time withstand current resistance: | 1 x 1s with 120 A |
Rated voltage (Use group B / CSA): | 300 V |
Rated voltage (Use group C / CSA): | 50 V |
Rated voltage (Use group D / CSA): | 300 V |
Rated current (Use group B / CSA): | 10 A |
Rated current (Use group D / CSA): | 10 A |
Wire cross-section, AWG, min.: | AWG 26 |
Wire cross-section, AWG, max.: | AWG 16 |
Certificate No. (cURus): | E60693 |
Rated voltage (Use group B / UL 1059): | 300 V |
Rated voltage (Use group C / UL 1059): | 50 V |
Rated voltage (Use group D / UL 1059): | 300 V |
Rated current (Use group D / UL 1059): | 10 A |
Wire cross-section, AWG, min.: | AWG 26 |
Wire cross-section, AWG, max.: | AWG 16 |
Reference to approval values: | Specifications are maximum values, details - see approval certificate. |
Packaging: | Box |
VPE length: | 0 m |
VPE width: | 0 m |
VPE height: | 0 m |
Standard: | IEC 60512-1-1:2002-02 |
Test: | dimensional inspection |
Evaluation: | passed |
Standard: | IEC 60512-1-2:2002-02 |
Test: | weight check |
Evaluation: | passed |
Standard: | IEC 61984:2001-10 section 6.2 |
Test: | visual examination |
Evaluation: | passed |
Standard: | IEC 60068-2-70:1995-12 test Xb |
Test: | mark of origin, type identification, pitch, type of material, date clock, approval marking UL, approval marking CSA |
Evaluation: | available |
Test: | durability |
Evaluation: | passed |
Standard: | IEC 60512-13-5:2006-02 |
Test: | 180° turned with coding elements |
Evaluation: | passed |
Test: | 180° turned without coding elements |
Evaluation: | passed |
Test: | visual examination |
Evaluation: | passed |
Standard: | IEC 60999-1:1999-11 section 9.1, IEC 60947-1:2011-03 section 8.2.4.5.1 |
Type of conductor and conductor cross-section: | solid 0.14 mm² |
Type of conductor and conductor cross-section: | stranded 0.14 mm² |
Type of conductor and conductor cross-section: | solid 1.5 mm² |
Type of conductor and conductor cross-section: | stranded 1.5 mm² |
Type of conductor and conductor cross-section: | AWG 26/1 |
Type of conductor and conductor cross-section: | AWG 26/19 |
Type of conductor and conductor cross-section: | AWG 16/1 |
Type of conductor and conductor cross-section: | AWG 16/19 |
Evaluation: | passed |
Standard: | IEC 60999-1:1999-11 section 9.4 bzw. section 8.10 |
Requirement: | 0.2 kg |
Type of conductor and conductor cross-section: | AWG 26/1 |
Type of conductor and conductor cross-section: | AWG 26/19 |
Evaluation: | passed |
Requirement: | 0.3 kg |
Type of conductor and conductor cross-section: | H05V-U0.5 |
Type of conductor and conductor cross-section: | H05V-K0.5 |
Evaluation: | passed |
Requirement: | 0.4 kg |
Type of conductor and conductor cross-section: | H07V-U1.5 |
Type of conductor and conductor cross-section: | H07V-K1.5 |
Type of conductor and conductor cross-section: | AWG 16/1 |
Type of conductor and conductor cross-section: | AWG 16/19 |
Evaluation: | passed |
Standard: | IEC 60999-1:1999-11 section 9.5 |
Requirement: | ≥10 N |
Type of conductor and conductor cross-section: | AWG 26/1 |
Type of conductor and conductor cross-section: | AWG 26/19 |
Evaluation: | passed |
Requirement: | ≥20 N |
Type of conductor and conductor cross-section: | H05V-U0.5 |
Type of conductor and conductor cross-section: | H05V-K0.5 |
Evaluation: | passed |
Requirement: | ≥40 N |
Type of conductor and conductor cross-section: | H07V-U1.5 |
Type of conductor and conductor cross-section: | H07V-K1.5 |
Type of conductor and conductor cross-section: | AWG 16/1 |
Type of conductor and conductor cross-section: | AWG 16/19 |
Evaluation: | passed |
ETIM 6.0: | EC002638 |
ETIM 7.0: | EC002638 |
eClass 9.0: | 27-44-03-09 |
eClass 9.1: | 27-44-03-09 |
eClass 10.0: | 27-44-03-09 |
IPC conformity: | Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request. |
ECCN: | |
Kraj pochodzenia: | |
EAN: | |
Waga: | 0,011 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |