Article image 2044850000

Weidmueller 2044850000

ACT20P-CML-10-AO-RC-S

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: ACT20P-CML-10-AO-RC-S
Order No.: 2044850000
Version: Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Analogue output, Screw connection, Input measurement range: configurable, 0…1/5/10 A AC (RMS) or DC
GTIN (EAN): 4050118409680
Qty.: 1 pc(s).
Width: 17.5 mm
Width (inches): 0.689 inch
Height: 119.2 mm
Height (inches): 4.693 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 141 g
Humidity: 5...95 %, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTTF: 130 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Input signal: Power cable can be connected to the terminals
Input measurement range: configurable, 0…1/5/10 A AC (RMS) or DC
Input frequency: AC: 15…400 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Accuracy: ≤ ±0.3 % @ 1 A ⁄ 5 A, ≤ ±0.6 % @ 10 A
Configuration: DIP switch and potentiometer
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.: 2.2 W
Rail: TS 35
Step response time: ≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient: ≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
Voltage supply: 16,8 V…31,2 V
EMC standards: IEC 61326-1, IEC 61010-2-201
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage: 6 kV (1.2/50 µs)
Pollution severity: 2
Surge voltage category: III
Load resistance current: ≤ 600 Ω
Load resistance voltage: ≥ 10 kΩ
Output current: Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage: Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output): Voltage and current output (configurable)
Alarm function: Surge current, Under-current, Alarm delay: 0…10 s
Number of digital outputs: 1
Type: Relay, 1 CO contact, normal / inverse adjustment
Max. switching voltage, DC: 24 V
Max. switching voltage, AC: 250 V
Rated switching current: 2 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002475
ETIM 7.0: EC002475
eClass 9.0: 27-21-01-23
eClass 9.1: 27-21-01-23
eClass 10.0: 27-21-01-23
ROHS: Conform
Type: ACT20P-CML-10-AO-RC-S
Order No.: 2044850000
Version: Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Analogue output, Screw connection, Input measurement range: configurable, 0…1/5/10 A AC (RMS) or DC
GTIN (EAN): 4050118409680
Qty.: 1 pc(s).
Width: 17.5 mm
Width (inches): 0.689 inch
Height: 119.2 mm
Height (inches): 4.693 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 141 g
Humidity: 5...95 %, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTTF: 130 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Input signal: Power cable can be connected to the terminals
Input measurement range: configurable, 0…1/5/10 A AC (RMS) or DC
Input frequency: AC: 15…400 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Accuracy: ≤ ±0.3 % @ 1 A ⁄ 5 A, ≤ ±0.6 % @ 10 A
Configuration: DIP switch and potentiometer
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.: 2.2 W
Rail: TS 35
Step response time: ≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient: ≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
Voltage supply: 16,8 V…31,2 V
EMC standards: IEC 61326-1, IEC 61010-2-201
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage: 6 kV (1.2/50 µs)
Pollution severity: 2
Surge voltage category: III
Load resistance current: ≤ 600 Ω
Load resistance voltage: ≥ 10 kΩ
Output current: Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage: Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output): Voltage and current output (configurable)
Alarm function: Surge current, Under-current, Alarm delay: 0…10 s
Number of digital outputs: 1
Type: Relay, 1 CO contact, normal / inverse adjustment
Max. switching voltage, DC: 24 V
Max. switching voltage, AC: 250 V
Rated switching current: 2 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002475
ETIM 7.0: EC002475
eClass 9.0: 27-21-01-23
eClass 9.1: 27-21-01-23
eClass 10.0: 27-21-01-23
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,195 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m