Article image 2026050000

Weidmueller 2026050000

VPU II 4W+G WYE 347V

2591270000

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Delivery status: This article will no longer be available in the future.
Available until: 2020-05-01
Type: VPU II 4W+G WYE 347V
Order No.: 2026050000
GTIN (EAN): 4050118405286
Qty.: 1 pc(s).
Width: 72 mm
Width (inches): 2.835 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 532 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...85 °C
Certificate No. (cURus): E354261
Continuous voltage UC, max.: 510 V
Rated voltage UN: 120 / 240 V
Rated Voltage UN: 347 V
Test Voltage 39.1 (UL 1449): 600 V
VPR (L/N-PE): 1,800 V
MCOV (L/N-PE): 510 Vac
SCCR: 200 kA
In: 20 kA
Category: SPD TYPE 1CA/2CA
Colour: black, orange
Design: Installation housing; 4TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 510 V
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 40 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Protection level Up at IN (L/N-PE): ≤ 2.1 kV
Number of poles: 4
Requirements category acc. to IEC 61643-11: Type II
Requirements class, acc. to EN 61643-11: T2
Response time: ≤ 25 ns
Signalling contact: No
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Wire connection cross section AWG, min.: AWG 14
Wire connection cross section AWG, max.: AWG 0
Wire cross-section, solid, min.: 4 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 25 mm²
Connection cross-section, stranded, min.: 4 mm²
Connection cross-section, stranded, max.: 50 mm²
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform
Delivery status: This article will no longer be available in the future.
Available until: 2020-05-01
Type: VPU II 4W+G WYE 347V
Order No.: 2026050000
GTIN (EAN): 4050118405286
Qty.: 1 pc(s).
Width: 72 mm
Width (inches): 2.835 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 532 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...85 °C
Certificate No. (cURus): E354261
Continuous voltage UC, max.: 510 V
Rated voltage UN: 120 / 240 V
Rated Voltage UN: 347 V
Test Voltage 39.1 (UL 1449): 600 V
VPR (L/N-PE): 1,800 V
MCOV (L/N-PE): 510 Vac
SCCR: 200 kA
In: 20 kA
Category: SPD TYPE 1CA/2CA
Colour: black, orange
Design: Installation housing; 4TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 510 V
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 40 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Protection level Up at IN (L/N-PE): ≤ 2.1 kV
Number of poles: 4
Requirements category acc. to IEC 61643-11: Type II
Requirements class, acc. to EN 61643-11: T2
Response time: ≤ 25 ns
Signalling contact: No
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Wire connection cross section AWG, min.: AWG 14
Wire connection cross section AWG, max.: AWG 0
Wire cross-section, solid, min.: 4 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 25 mm²
Connection cross-section, stranded, min.: 4 mm²
Connection cross-section, stranded, max.: 50 mm²
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m