1510290000
ACT20P-CMT-60-AO-RC-P
| Type: | ACT20P-CMT-60-AO-RC-P |
| Order No.: | 1510290000 |
| Version: | Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Analogue output, PUSH IN connection, Input measurement range: configurable, 0…40/50/60 A AC or DC |
| GTIN (EAN): | 4050118319552 |
| Qty.: | 1 pc(s). |
| Width: | 22.8 mm |
| Width (inches): | 0.898 inch |
| Height: | 127.1 mm |
| Height (inches): | 5.004 inch |
| Depth: | 114 mm |
| Depth (inches): | 4.488 inch |
| Net weight: | 158 g |
| Humidity: | 5...95 %, no condensation |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -25 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -25 °C...60 °C |
| Storage temperature: | -40 °C...85 °C |
| MTTF: | 158 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Input signal: | Current-carrying cable in feed-through hole, Diameter 10.5 mm |
| Input measurement range: | configurable, 0…40/50/60 A AC or DC |
| Input frequency: | AC: 15…700 Hz (true root mean square), AC: 50 Hz (arithmetic average) |
| Accuracy: | < 0.75 % FSR |
| Configuration: | DIP switch and potentiometer, for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Power consumption, max.: | 2.2 W |
| Rail: | TS 35 |
| Step response time: | ≤ 300 ms (RMS), ≤ 60 ms (AA) |
| Temperature coefficient: | 0.01%/K @ 0...40 A, 0.10%/K @ 40...55 A, 0.30%/K @ 55...60 A |
| Voltage supply: | 16,8 V…31,2 V |
| EMC standards: | IEC 61326-1, IEC 61010-2-201 |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Impulse withstand voltage: | 6.4 kV (1.2/50 µs) |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Load resistance current: | ≤ 600 Ω |
| Load resistance voltage: | ≥ 10 kΩ |
| Output current: | Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA |
| Output voltage: | Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V |
| Type (analogue output): | Voltage and current output (configurable) |
| Alarm function: | Surge current, Under-current, Alarm delay: 0…10 s, Hysteresis 5% / 10% |
| Number of digital outputs: | 1 |
| Type: | Relay, 1 CO contact, normal / inverse adjustment |
| Max. switching voltage, DC: | 24 V |
| Max. switching voltage, AC: | 250 V |
| Rated switching current: | 6 A |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002475 |
| ETIM 7.0: | EC002475 |
| eClass 9.0: | 27-21-01-23 |
| eClass 9.1: | 27-21-01-23 |
| eClass 10.0: | 27-21-01-23 |
| Approvals: | CULUS; |
| ROHS: | Conform |
| Type: | ACT20P-CMT-60-AO-RC-P |
| Order No.: | 1510290000 |
| Version: | Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Analogue output, PUSH IN connection, Input measurement range: configurable, 0…40/50/60 A AC or DC |
| GTIN (EAN): | 4050118319552 |
| Qty.: | 1 pc(s). |
| Width: | 22.8 mm |
| Width (inches): | 0.898 inch |
| Height: | 127.1 mm |
| Height (inches): | 5.004 inch |
| Depth: | 114 mm |
| Depth (inches): | 4.488 inch |
| Net weight: | 158 g |
| Humidity: | 5...95 %, no condensation |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -25 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -25 °C...60 °C |
| Storage temperature: | -40 °C...85 °C |
| MTTF: | 158 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Input signal: | Current-carrying cable in feed-through hole, Diameter 10.5 mm |
| Input measurement range: | configurable, 0…40/50/60 A AC or DC |
| Input frequency: | AC: 15…700 Hz (true root mean square), AC: 50 Hz (arithmetic average) |
| Accuracy: | < 0.75 % FSR |
| Configuration: | DIP switch and potentiometer, for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Power consumption, max.: | 2.2 W |
| Rail: | TS 35 |
| Step response time: | ≤ 300 ms (RMS), ≤ 60 ms (AA) |
| Temperature coefficient: | 0.01%/K @ 0...40 A, 0.10%/K @ 40...55 A, 0.30%/K @ 55...60 A |
| Voltage supply: | 16,8 V…31,2 V |
| EMC standards: | IEC 61326-1, IEC 61010-2-201 |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Impulse withstand voltage: | 6.4 kV (1.2/50 µs) |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Load resistance current: | ≤ 600 Ω |
| Load resistance voltage: | ≥ 10 kΩ |
| Output current: | Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA |
| Output voltage: | Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V |
| Type (analogue output): | Voltage and current output (configurable) |
| Alarm function: | Surge current, Under-current, Alarm delay: 0…10 s, Hysteresis 5% / 10% |
| Number of digital outputs: | 1 |
| Type: | Relay, 1 CO contact, normal / inverse adjustment |
| Max. switching voltage, DC: | 24 V |
| Max. switching voltage, AC: | 250 V |
| Rated switching current: | 6 A |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002475 |
| ETIM 7.0: | EC002475 |
| eClass 9.0: | 27-21-01-23 |
| eClass 9.1: | 27-21-01-23 |
| eClass 10.0: | 27-21-01-23 |
| Approvals: | CULUS; |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,206 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |