1453210000
ACT20P-UI-AO-DO-LP-S
| Type: | ACT20P-UI-AO-DO-LP-S |
| Order No.: | 1453210000 |
| Version: | Signal converter/insulator, Limit value monitoring, Input: temperature, R, U, I, Output: 4 - 20 mA, Output current loop powered, Input : universal U, I, R,ϑ, Output : 4-20 mA |
| GTIN (EAN): | 4050118259605 |
| Qty.: | 1 pc(s). |
| Width: | 12.5 mm |
| Width (inches): | 0.492 inch |
| Height: | 119.2 mm |
| Height (inches): | 4.693 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Net weight: | 157 g |
| Humidity: | 10…90 %, no condensation |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 70 °C |
| Storage temperature, min.: | -20 °C |
| Operating temperature: | -20 °C...70 °C |
| Ambient temperature: | -20 °C...+70 °C |
| Storage temperature: | -20 °C...70 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Type: | Universal signal isolator / signal amplifier, thermocouple, RTD |
| Sensor: | PT100 (2-/3- wire), PT1000 (2-/3- wire), PT200, N120, Cu 10, Thermocouples: B, E, J, K, L, N, R, S, T, U |
| Sensor supply: | 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable |
| Influence of the sensor cable resistance: | 5 Ω @ RTD- Kabel |
| Input voltage: | configurable, -150…+150 mV DC (min. measurement range15 mV), -600…+600 mV DC (min. measurement range 50 mV), ± 12 V DC (min. measurement range 1 V), ± 28 V DC (min. measurement range 2 V), ± 300 V DC (min. measurement range 100 V), 0…1 V AC (min. measurement range300 mV), 0…250 V AC (min. measurement range 100 V) |
| Input resistance, voltage: | > 10 MΩ @ 600 mV, 2 MΩ |
| Input current: | configurable, ± 5 A DC (min. measurement range 0.5 A) |
| Input resistance, current: | 40 Ω |
| Cable-length compensation: | < ±0.002 Ω per cable resistance Ω |
| Temperature input range: | CU10: -100…+260 °C, Ni120: -80 °C…+320 °C, PT100 / 200 / 1000: -200 °C…+850 °C, B: +100…+1820 °C, E: -270…+1000 °C, J: -270…+1200 °C, K: -270…+1372 °C, L: +100…+900 °C, N: -180…+1300 °C, R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C |
| Resistance: | 0…750 Ω, 0…1.5 kΩ, 0…12 kΩ |
| Potentiometer: | 1.2…500 kΩ |
| Accuracy: | < 0.1 % of measuring range |
| Cold-junction compensation error: | ±1.0°C @ -20° C - 65°C |
| Configuration: | With FDT/DTM software |
| Galvanic isolation: | 2-way isolator, between input/output |
| Rail: | TS 35 |
| Step response time: | 450 ms |
| Temperature coefficient: | < 0.02 °C of measuring range / °C |
| Voltage supply: | Output loop powered, (10…45 V) |
| Galvanic isolation: | 2-way isolator, between input/output |
| Impulse withstand voltage: | 4 kV (1.2/50 µs) |
| Insulation voltage: | 3.51 kV between input and output |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Output current: | 4...20 mA (current loop) |
| Signal output: | direct or inverted |
| Alarm function: | configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s |
| Hysteresis: | ≥ 0.1 % of FS |
| Number of digital outputs: | 1 |
| Type: | Transistor, open collector |
| Rated switching current: | 20 mA |
| Rated switching voltage: | ≤ 30 V DC |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.6 Nm |
| Clamping range, rated connection: | 2.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 12 |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| Approvals: | CULUS; |
| ROHS: | Conform |
| Type: | ACT20P-UI-AO-DO-LP-S |
| Order No.: | 1453210000 |
| Version: | Signal converter/insulator, Limit value monitoring, Input: temperature, R, U, I, Output: 4 - 20 mA, Output current loop powered, Input : universal U, I, R,ϑ, Output : 4-20 mA |
| GTIN (EAN): | 4050118259605 |
| Qty.: | 1 pc(s). |
| Width: | 12.5 mm |
| Width (inches): | 0.492 inch |
| Height: | 119.2 mm |
| Height (inches): | 4.693 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Net weight: | 157 g |
| Humidity: | 10…90 %, no condensation |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 70 °C |
| Storage temperature, min.: | -20 °C |
| Operating temperature: | -20 °C...70 °C |
| Ambient temperature: | -20 °C...+70 °C |
| Storage temperature: | -20 °C...70 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Type: | Universal signal isolator / signal amplifier, thermocouple, RTD |
| Sensor: | PT100 (2-/3- wire), PT1000 (2-/3- wire), PT200, N120, Cu 10, Thermocouples: B, E, J, K, L, N, R, S, T, U |
| Sensor supply: | 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable |
| Influence of the sensor cable resistance: | 5 Ω @ RTD- Kabel |
| Input voltage: | configurable, -150…+150 mV DC (min. measurement range15 mV), -600…+600 mV DC (min. measurement range 50 mV), ± 12 V DC (min. measurement range 1 V), ± 28 V DC (min. measurement range 2 V), ± 300 V DC (min. measurement range 100 V), 0…1 V AC (min. measurement range300 mV), 0…250 V AC (min. measurement range 100 V) |
| Input resistance, voltage: | > 10 MΩ @ 600 mV, 2 MΩ |
| Input current: | configurable, ± 5 A DC (min. measurement range 0.5 A) |
| Input resistance, current: | 40 Ω |
| Cable-length compensation: | < ±0.002 Ω per cable resistance Ω |
| Temperature input range: | CU10: -100…+260 °C, Ni120: -80 °C…+320 °C, PT100 / 200 / 1000: -200 °C…+850 °C, B: +100…+1820 °C, E: -270…+1000 °C, J: -270…+1200 °C, K: -270…+1372 °C, L: +100…+900 °C, N: -180…+1300 °C, R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C |
| Resistance: | 0…750 Ω, 0…1.5 kΩ, 0…12 kΩ |
| Potentiometer: | 1.2…500 kΩ |
| Accuracy: | < 0.1 % of measuring range |
| Cold-junction compensation error: | ±1.0°C @ -20° C - 65°C |
| Configuration: | With FDT/DTM software |
| Galvanic isolation: | 2-way isolator, between input/output |
| Rail: | TS 35 |
| Step response time: | 450 ms |
| Temperature coefficient: | < 0.02 °C of measuring range / °C |
| Voltage supply: | Output loop powered, (10…45 V) |
| Galvanic isolation: | 2-way isolator, between input/output |
| Impulse withstand voltage: | 4 kV (1.2/50 µs) |
| Insulation voltage: | 3.51 kV between input and output |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Output current: | 4...20 mA (current loop) |
| Signal output: | direct or inverted |
| Alarm function: | configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s |
| Hysteresis: | ≥ 0.1 % of FS |
| Number of digital outputs: | 1 |
| Type: | Transistor, open collector |
| Rated switching current: | 20 mA |
| Rated switching voltage: | ≤ 30 V DC |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.6 Nm |
| Clamping range, rated connection: | 2.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 12 |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| Approvals: | CULUS; |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,174 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |