Type: ACT20M-RTI-CO-EOLP-S
Order No.: 1435610000
Version: Temperature converter, 2-/3-/4- wire RTD, Input : Temperature, Output : 4-20 mA, (loop powered)
GTIN (EAN): 4050118240528
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 80 g
Humidity: 40 °C / 93 % rel. humidity, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 227 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: PT100 / 2-/3-/4-wire
Influence of the sensor cable resistance: < 0.002 Ω⁄Ω
Input measurement range: PT100 -200…+850 °C
Line resistance in measuring circuit: 50 Ω@ RTD (Pt100), 10 kΩ @ TC (J, K)
Temperature input range: Configurable, min. measurement range 10°C (RTD)
Number of outputs: 1
Output current: configurable, 4...20 mA, 20…4 mA
Wire break detection: 3.5 mA ⁄ 23 mA ⁄ none
Accuracy: absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±0.2°C
Cold-junction compensation error: ±(2.0 °C + 0.4 °C x Δt) Δt = inside temperature – ambient temperature
Configuration: DIP switch
Setting parameters: Output
Configuration: 4...20 mA (loop)
Setting parameters: Sensor error detection
Configuration: enabled
Setting parameters: Output error level
Configuration: downscale
Setting parameters: Noise suppression
Configuration: 50 Hz
Setting parameters: Step response time
Configuration: < 30 ms
Setting parameters: Start temperature
Configuration: -200 °C
Setting parameters: End temperature
Configuration: 0 °C
Galvanic isolation: Without isolation
Power consumption, max.: 0.8 W
Power consumption, typ.: 0.48 W
Rail: TS 35
Step response time: ≤ 30 ms, < 300 ms
Temperature coefficient: RTD (PT100) ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C
Voltage supply: Output loop powered, 6…35 V
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: Without isolation
Pollution severity: 2
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
ETIM 6.0: EC002919
ETIM 7.0: EC002919
eClass 9.0: 27-21-01-29
eClass 9.1: 27-21-01-29
eClass 10.0: 27-21-01-29
ROHS: Conform
Type: ACT20M-RTI-CO-EOLP-S
Order No.: 1435610000
Version: Temperature converter, 2-/3-/4- wire RTD, Input : Temperature, Output : 4-20 mA, (loop powered)
GTIN (EAN): 4050118240528
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 80 g
Humidity: 40 °C / 93 % rel. humidity, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 227 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: PT100 / 2-/3-/4-wire
Influence of the sensor cable resistance: < 0.002 Ω⁄Ω
Input measurement range: PT100 -200…+850 °C
Line resistance in measuring circuit: 50 Ω@ RTD (Pt100), 10 kΩ @ TC (J, K)
Temperature input range: Configurable, min. measurement range 10°C (RTD)
Number of outputs: 1
Output current: configurable, 4...20 mA, 20…4 mA
Wire break detection: 3.5 mA ⁄ 23 mA ⁄ none
Accuracy: absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±0.2°C
Cold-junction compensation error: ±(2.0 °C + 0.4 °C x Δt) Δt = inside temperature – ambient temperature
Configuration: DIP switch
Setting parameters: Output
Configuration: 4...20 mA (loop)
Setting parameters: Sensor error detection
Configuration: enabled
Setting parameters: Output error level
Configuration: downscale
Setting parameters: Noise suppression
Configuration: 50 Hz
Setting parameters: Step response time
Configuration: < 30 ms
Setting parameters: Start temperature
Configuration: -200 °C
Setting parameters: End temperature
Configuration: 0 °C
Galvanic isolation: Without isolation
Power consumption, max.: 0.8 W
Power consumption, typ.: 0.48 W
Rail: TS 35
Step response time: ≤ 30 ms, < 300 ms
Temperature coefficient: RTD (PT100) ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C
Voltage supply: Output loop powered, 6…35 V
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: Without isolation
Pollution severity: 2
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
ETIM 6.0: EC002919
ETIM 7.0: EC002919
eClass 9.0: 27-21-01-29
eClass 9.1: 27-21-01-29
eClass 10.0: 27-21-01-29
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,089 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m