1352870000
VPU II 2 R 400V/40KA
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU II 2 R 400V/40KA |
| Order No.: | 1352870000 |
| Version: | Surge voltage arrester, Low voltage, with remote contact, Single-phase |
| GTIN (EAN): | 4050118157536 |
| Qty.: | 1 pc(s). |
| Width: | 35.6 mm |
| Width (inches): | 1.402 inch |
| Height: | 106 mm |
| Height (inches): | 4.173 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 298 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Connection type: | PUSH IN |
| Stripping length: | 8 mm |
| Cross-section for connected wire, solid core, min.: | 0.14 mm² |
| Cross-section for connected wire, solid core, max.: | 1.5 mm² |
| Colour: | black, orange |
| Design: | Installation housing; 2TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | with remote contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 400 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 400 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 40 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 2.1 kV |
| Leakage current at Un: | 150 µA |
| Temporary surge voltage (over-voltage) - TOV: | 620 V |
| Combined pulse UOC: | 10 kV |
| Number of poles: | 2 |
| Requirements category acc. to IEC 61643-11: | Type II, Type III |
| Requirements class, acc. to EN 61643-11: | T2, T3 |
| Response time: | ≤ 25 ns |
| Signalling contact: | 250 V 1A 1CO |
| Wire connection method: | Screw connection |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Multi-pole lightning arrestor according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor provides overvoltage protection in applications acc. to IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU II 2 R 400 V/40 kA is used in the single-phase mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (changeover). Rated voltage: 400 VAC In/max (8/20 µs): 20/40 kA protection level < 2.1 kV 25 kA short-circuit strength with max. back-up fuse of 125 A gl telecommunication output: contact: 250 V/0.5 A |
| Short specification: | Class II arrester with In/Imax: 20/40 kA suitable for single-phase 400 V TN-C mains systems. Protection level < 2.1 kV. With remote alert Type: Weidmüller VPU II 2 R 400 V/40 kA Order no. 1352870000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU II 2 R 400V/40KA |
| Order No.: | 1352870000 |
| Version: | Surge voltage arrester, Low voltage, with remote contact, Single-phase |
| GTIN (EAN): | 4050118157536 |
| Qty.: | 1 pc(s). |
| Width: | 35.6 mm |
| Width (inches): | 1.402 inch |
| Height: | 106 mm |
| Height (inches): | 4.173 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 298 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Connection type: | PUSH IN |
| Stripping length: | 8 mm |
| Cross-section for connected wire, solid core, min.: | 0.14 mm² |
| Cross-section for connected wire, solid core, max.: | 1.5 mm² |
| Colour: | black, orange |
| Design: | Installation housing; 2TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | with remote contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 400 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 400 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 40 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 2.1 kV |
| Leakage current at Un: | 150 µA |
| Temporary surge voltage (over-voltage) - TOV: | 620 V |
| Combined pulse UOC: | 10 kV |
| Number of poles: | 2 |
| Requirements category acc. to IEC 61643-11: | Type II, Type III |
| Requirements class, acc. to EN 61643-11: | T2, T3 |
| Response time: | ≤ 25 ns |
| Signalling contact: | 250 V 1A 1CO |
| Wire connection method: | Screw connection |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Multi-pole lightning arrestor according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor provides overvoltage protection in applications acc. to IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU II 2 R 400 V/40 kA is used in the single-phase mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (changeover). Rated voltage: 400 VAC In/max (8/20 µs): 20/40 kA protection level < 2.1 kV 25 kA short-circuit strength with max. back-up fuse of 125 A gl telecommunication output: contact: 250 V/0.5 A |
| Short specification: | Class II arrester with In/Imax: 20/40 kA suitable for single-phase 400 V TN-C mains systems. Protection level < 2.1 kV. With remote alert Type: Weidmüller VPU II 2 R 400 V/40 kA Order no. 1352870000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,304 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |