1352580000
VPU II 1 280V/40KA
2591020000
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU II 1 280V/40KA |
| Order No.: | 1352580000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase |
| GTIN (EAN): | 4050118157765 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 142 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 1TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 230 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 280 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 40 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.55 kV |
| Leakage current at Un: | 30 µA |
| Temporary surge voltage (over-voltage) - TOV: | 438 V |
| Combined pulse UOC: | 10 kV |
| Number of poles: | 1 |
| Requirements category acc. to IEC 61643-11: | Type II, Type III |
| Requirements class, acc. to EN 61643-11: | T2, T3 |
| Response time: | ≤ 25 ns |
| Signalling contact: | No |
| Wire connection method: | Screw connection |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Single-pole surge protection according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor serves as surge protection and is used in applications according to IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU II 1 280 V/40 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor). Reference is also made here to the 3+1 circuit and the 3+0 / 4+0 circuits. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window change |
| Short specification: | Class II arrester with In/Imax: 20/40 kA suitable for 230/400 V mains systems. Protection level < 1.55 kV. Type: Weidmüller VPU II 1 280 V/40 kA Order no. 1352580000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU II 1 280V/40KA |
| Order No.: | 1352580000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase |
| GTIN (EAN): | 4050118157765 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 142 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 1TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 230 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 280 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 40 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.55 kV |
| Leakage current at Un: | 30 µA |
| Temporary surge voltage (over-voltage) - TOV: | 438 V |
| Combined pulse UOC: | 10 kV |
| Number of poles: | 1 |
| Requirements category acc. to IEC 61643-11: | Type II, Type III |
| Requirements class, acc. to EN 61643-11: | T2, T3 |
| Response time: | ≤ 25 ns |
| Signalling contact: | No |
| Wire connection method: | Screw connection |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Single-pole surge protection according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor serves as surge protection and is used in applications according to IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU II 1 280 V/40 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor). Reference is also made here to the 3+1 circuit and the 3+0 / 4+0 circuits. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window change |
| Short specification: | Class II arrester with In/Imax: 20/40 kA suitable for 230/400 V mains systems. Protection level < 1.55 kV. Type: Weidmüller VPU II 1 280 V/40 kA Order no. 1352580000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |