Article image 1352350000

Weidmueller 1352350000

VPU I 3 R 400V/12,5KA

2591540000

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Delivery status: This article will no longer be available in the future.
Available until: 2020-05-01
Type: VPU I 3 R 400V/12,5KA
Order No.: 1352350000
Version: Surge voltage arrester, Low voltage, with remote contact, TN-C
GTIN (EAN): 4050118157932
Qty.: 1 pc(s).
Width: 53.4 mm
Width (inches): 2.102 inch
Height: 106 mm
Height (inches): 4.173 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 600 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Connection type: PUSH IN
Stripping length: 8 mm
Cross-section for connected wire, solid core, min.: 0.14 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black, orange
Design: Installation housing; 3TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: with remote contact
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 400 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 400 V
Low voltage network: TN-C
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 50 kA
Lightning test current Iimp (10/350 µs) (L-PE): 12.5 kA
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.8 kV
Leakage current at Un: 100 µA
Temporary surge voltage (over-voltage) - TOV: 620 V
Number of poles: 3
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Signalling contact: 250 V 1A 1CO
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 4 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 2.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 2.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (in accordance with IEC 1312-1), the arrestor, made from V0 material, serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class I surge protection systems according to the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 3 R 400/690 V/12.5 kA is used in the single-phase TN-S mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (changeover). Rated volta
Short specification: Class I arrester for LPL III/IV with 12.5 kA suitable for 400/690 V TN-C mains systems. Protection level < 1.8 kV. With remote alert Type: Weidmüller VPU I 3 R 400 V/12.5 kA Order no. 1352350000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform
Delivery status: This article will no longer be available in the future.
Available until: 2020-05-01
Type: VPU I 3 R 400V/12,5KA
Order No.: 1352350000
Version: Surge voltage arrester, Low voltage, with remote contact, TN-C
GTIN (EAN): 4050118157932
Qty.: 1 pc(s).
Width: 53.4 mm
Width (inches): 2.102 inch
Height: 106 mm
Height (inches): 4.173 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 600 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Connection type: PUSH IN
Stripping length: 8 mm
Cross-section for connected wire, solid core, min.: 0.14 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black, orange
Design: Installation housing; 3TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: with remote contact
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 400 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 400 V
Low voltage network: TN-C
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 50 kA
Lightning test current Iimp (10/350 µs) (L-PE): 12.5 kA
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.8 kV
Leakage current at Un: 100 µA
Temporary surge voltage (over-voltage) - TOV: 620 V
Number of poles: 3
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Signalling contact: 250 V 1A 1CO
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 4 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 2.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 2.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (in accordance with IEC 1312-1), the arrestor, made from V0 material, serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class I surge protection systems according to the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 3 R 400/690 V/12.5 kA is used in the single-phase TN-S mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (changeover). Rated volta
Short specification: Class I arrester for LPL III/IV with 12.5 kA suitable for 400/690 V TN-C mains systems. Protection level < 1.8 kV. With remote alert Type: Weidmüller VPU I 3 R 400 V/12.5 kA Order no. 1352350000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m