1352340000
VPU I 3 400V/12,5KA
2591530000
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU I 3 400V/12,5KA |
| Order No.: | 1352340000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, TN-C |
| GTIN (EAN): | 4050118157949 |
| Qty.: | 1 pc(s). |
| Width: | 53.4 mm |
| Width (inches): | 2.102 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 594 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 3TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Power distribution |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | IV |
| Rated voltage (AC): | 400 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 400 V |
| Low voltage network: | TN-C |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 50 kA |
| Lightning test current Iimp (10/350 µs) (L-PE): | 12.5 kA |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type I, Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 100 µA |
| Temporary surge voltage (over-voltage) - TOV: | 620 V |
| Number of poles: | 3 |
| Requirements category acc. to IEC 61643-11: | Type I, Type II |
| Requirements class, acc. to EN 61643-11: | T1, T2 |
| Response time: | ≤ 25 ns |
| Signalling contact: | No |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 4 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 2.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 2.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 2.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Multi-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (in accordance with IEC 1312-1), the arrestor, made from V0 material, serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class I surge protection systems according to the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 3 R 400/690 V/12.5 kA is used in the TN-C mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 230 VAC lightning test current (10/350 µs): 12.5 kA protection level with lightning test current < |
| Short specification: | Class I arrester for LPL III/IV with 12.5 kA suitable for 400/690 V TN-C mains systems. Protection level < 1.8 kV. With remote alert Type: Weidmüller VPU I 3 R 400 V/12.5 kA Order no. 1352340000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-22 |
| ROHS: | Conform |
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU I 3 400V/12,5KA |
| Order No.: | 1352340000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, TN-C |
| GTIN (EAN): | 4050118157949 |
| Qty.: | 1 pc(s). |
| Width: | 53.4 mm |
| Width (inches): | 2.102 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 594 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 3TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Power distribution |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | IV |
| Rated voltage (AC): | 400 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 400 V |
| Low voltage network: | TN-C |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 50 kA |
| Lightning test current Iimp (10/350 µs) (L-PE): | 12.5 kA |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type I, Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 100 µA |
| Temporary surge voltage (over-voltage) - TOV: | 620 V |
| Number of poles: | 3 |
| Requirements category acc. to IEC 61643-11: | Type I, Type II |
| Requirements class, acc. to EN 61643-11: | T1, T2 |
| Response time: | ≤ 25 ns |
| Signalling contact: | No |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 4 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 2.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 2.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 2.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Multi-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (in accordance with IEC 1312-1), the arrestor, made from V0 material, serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for Class I surge protection systems according to the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 3 R 400/690 V/12.5 kA is used in the TN-C mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 230 VAC lightning test current (10/350 µs): 12.5 kA protection level with lightning test current < |
| Short specification: | Class I arrester for LPL III/IV with 12.5 kA suitable for 400/690 V TN-C mains systems. Protection level < 1.8 kV. With remote alert Type: Weidmüller VPU I 3 R 400 V/12.5 kA Order no. 1352340000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-22 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |