1352280000
VPU I 0 400V/12,5KA
| Type: | VPU I 0 400V/12,5KA |
| Order No.: | 1352280000 |
| Version: | Surge voltage arrester, Low voltage, Accessories, Spare arrester |
| GTIN (EAN): | 4050118157994 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 52 mm |
| Height (inches): | 2.047 inch |
| Depth: | 64 mm |
| Depth (inches): | 2.52 inch |
| Net weight: | 155 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | orange |
| Design: | Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Segment: | Power distribution |
| UL 94 flammability rating: | V-0 |
| Version: | Spare arrester |
| Pollution severity: | 2 |
| Surge voltage category: | IV |
| Rated voltage (AC): | 400 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 400 V |
| Discharge current In (8/20µs) wire-PE: | 25 kA |
| Discharge current Imax (8/20µs) wire-PE: | 50 kA |
| Lightning test current Iimp (10/350 µs) (L-PE): | 12.5 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A) |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 30 µA |
| Temporary surge voltage (over-voltage) - TOV: | 620 V |
| Number of poles: | 1 |
| Requirements category acc. to IEC 61643-11: | Type I, Type II |
| Requirements class, acc. to EN 61643-11: | T1, T2 |
| Response time: | ≤ 25 ns |
| Type of connection: | pluggable |
| Long specification: | Spare arrestor for VPU I 0 280 V LCF-series surge voltage arrestor with 12.5 kA. The pluggable high-performance varistors made from V0 material can be replaced by trained personnel following a failure. Rated voltage: 400 V LCF Type: Weidmüller VPU I 0 LCF 400 V/12.5 kA Order No.: 1352280000 |
| Short specification: | Spare arrester for surge voltage arrester VPU I 0 280 V LCF series with 12.5 kA. The pluggable high-performance varistors can be swapped by trained personnel following a failure. Rated voltage: 400 V LCF Type: Weidmüller VPU I 0 LCF 400 V/12.5 kA Order no.: 1352280000 |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-22 |
| ROHS: | Conform |
| Type: | VPU I 0 400V/12,5KA |
| Order No.: | 1352280000 |
| Version: | Surge voltage arrester, Low voltage, Accessories, Spare arrester |
| GTIN (EAN): | 4050118157994 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 52 mm |
| Height (inches): | 2.047 inch |
| Depth: | 64 mm |
| Depth (inches): | 2.52 inch |
| Net weight: | 155 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | orange |
| Design: | Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Segment: | Power distribution |
| UL 94 flammability rating: | V-0 |
| Version: | Spare arrester |
| Pollution severity: | 2 |
| Surge voltage category: | IV |
| Rated voltage (AC): | 400 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 400 V |
| Discharge current In (8/20µs) wire-PE: | 25 kA |
| Discharge current Imax (8/20µs) wire-PE: | 50 kA |
| Lightning test current Iimp (10/350 µs) (L-PE): | 12.5 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A) |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 30 µA |
| Temporary surge voltage (over-voltage) - TOV: | 620 V |
| Number of poles: | 1 |
| Requirements category acc. to IEC 61643-11: | Type I, Type II |
| Requirements class, acc. to EN 61643-11: | T1, T2 |
| Response time: | ≤ 25 ns |
| Type of connection: | pluggable |
| Long specification: | Spare arrestor for VPU I 0 280 V LCF-series surge voltage arrestor with 12.5 kA. The pluggable high-performance varistors made from V0 material can be replaced by trained personnel following a failure. Rated voltage: 400 V LCF Type: Weidmüller VPU I 0 LCF 400 V/12.5 kA Order No.: 1352280000 |
| Short specification: | Spare arrester for surge voltage arrester VPU I 0 280 V LCF series with 12.5 kA. The pluggable high-performance varistors can be swapped by trained personnel following a failure. Rated voltage: 400 V LCF Type: Weidmüller VPU I 0 LCF 400 V/12.5 kA Order no.: 1352280000 |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-22 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,155 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |