Article image 1352120000

Weidmueller 1352120000

VPU I 0 280V/12,5KA

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: VPU I 0 280V/12,5KA
Order No.: 1352120000
Version: Surge voltage arrester, Low voltage, Accessories, Spare arrester
GTIN (EAN): 4050118158120
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 52 mm
Height (inches): 2.047 inch
Depth: 64 mm
Depth (inches): 2.52 inch
Net weight: 129 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: orange
Design: Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Segment: Power distribution
UL 94 flammability rating: V-0
Version: Spare arrester
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 280 V
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 50 kA
Lightning test current Iimp (10/350 µs) (L-PE): 12.5 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Protection level Up at IN (L/N-PE): ≤ 1.4 kV
Leakage current at Un: 100 µA
Temporary surge voltage (over-voltage) - TOV: 438 V
Number of poles: 1
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Type of connection: pluggable
Long specification: Spare arrestor for VPU I 280 V-series surge voltage arrestor with 12.5 kA. The pluggable high-performance varistors made from V0 material can be replaced by trained personnel following a failure. Rated voltage: 280 V Type: Weidmüller VPU I 0 280 V/12.5 kA Order No.: 1352120000
Short specification: Spare arrestor for VPU I 280 V-series surge voltage arrestor with 12.5 kA. The pluggable high-performance varistors can be replaced by trained personnel following a failure. Rated voltage: 280 V Type: Weidmüller VPU I 0 280 V/12.5 kA Order No.: 1352120000
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform
Type: VPU I 0 280V/12,5KA
Order No.: 1352120000
Version: Surge voltage arrester, Low voltage, Accessories, Spare arrester
GTIN (EAN): 4050118158120
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 52 mm
Height (inches): 2.047 inch
Depth: 64 mm
Depth (inches): 2.52 inch
Net weight: 129 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: orange
Design: Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Segment: Power distribution
UL 94 flammability rating: V-0
Version: Spare arrester
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 280 V
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 50 kA
Lightning test current Iimp (10/350 µs) (L-PE): 12.5 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Protection level Up at IN (L/N-PE): ≤ 1.4 kV
Leakage current at Un: 100 µA
Temporary surge voltage (over-voltage) - TOV: 438 V
Number of poles: 1
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Type of connection: pluggable
Long specification: Spare arrestor for VPU I 280 V-series surge voltage arrestor with 12.5 kA. The pluggable high-performance varistors made from V0 material can be replaced by trained personnel following a failure. Rated voltage: 280 V Type: Weidmüller VPU I 0 280 V/12.5 kA Order No.: 1352120000
Short specification: Spare arrestor for VPU I 280 V-series surge voltage arrestor with 12.5 kA. The pluggable high-performance varistors can be replaced by trained personnel following a failure. Rated voltage: 280 V Type: Weidmüller VPU I 0 280 V/12.5 kA Order No.: 1352120000
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,129 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m