Article image 1351820000

Weidmueller 1351820000

VPU I 1 400V/25KA

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: VPU I 1 400V/25KA
Order No.: 1351820000
Version: Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase
GTIN (EAN): 4050118158366
Qty.: 1 pc(s).
Width: 35.6 mm
Width (inches): 1.402 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 411 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 2TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 400 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 400 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 100 kA
Lightning test current Iimp (10/350 µs) (L-PE): 25 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.9 kV
Leakage current at Un: 100 µA
Temporary surge voltage (over-voltage) - TOV: 620 V
Number of poles: 1
Rated load current IL: 100 A
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Signalling contact: No
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 4 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 2.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 2.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Single-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. Made from V0 material, the arrestor serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12 on interface transition from 0 to 1 (according to IEC 1312-1). Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a non-blow-out sparkover gap, in combination with a high-power varistor, satisfies the inspection requirements for Class I surge protection systems in accordance with the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 1 R 400 V/25 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor
Short specification: Class I arrester for LPL 1 with 25 kA suitable for 400/690 V mains systems. Protection level < 1.9 kV. Type: Weidmüller VPU I 1 400 V/25 kA Order no. 1351820000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform
Type: VPU I 1 400V/25KA
Order No.: 1351820000
Version: Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase
GTIN (EAN): 4050118158366
Qty.: 1 pc(s).
Width: 35.6 mm
Width (inches): 1.402 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 411 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 2TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 400 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 400 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 100 kA
Lightning test current Iimp (10/350 µs) (L-PE): 25 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.9 kV
Leakage current at Un: 100 µA
Temporary surge voltage (over-voltage) - TOV: 620 V
Number of poles: 1
Rated load current IL: 100 A
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Signalling contact: No
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 4 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 2.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 2.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Single-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. Made from V0 material, the arrestor serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12 on interface transition from 0 to 1 (according to IEC 1312-1). Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a non-blow-out sparkover gap, in combination with a high-power varistor, satisfies the inspection requirements for Class I surge protection systems in accordance with the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 1 R 400 V/25 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor
Short specification: Class I arrester for LPL 1 with 25 kA suitable for 400/690 V mains systems. Protection level < 1.9 kV. Type: Weidmüller VPU I 1 400 V/25 kA Order no. 1351820000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,411 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m