Article image 1351680000

Weidmueller 1351680000

VPU III SO LD

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: VPU III SO LD
Order No.: 1351680000
GTIN (EAN): 4050118158472
Qty.: 1 pc(s).
Width: 12 mm
Width (inches): 0.472 inch
Height: 35 mm
Height (inches): 1.378 inch
Depth: 25 mm
Depth (inches): 0.984 inch
Net weight: 34 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 55 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...55 °C
Storage temperature: -40 °C...80 °C
Connection type: Miscellaneous
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black
Design: Flush mounting
Optical function display: Green LED = OK, Red LED = arrester is defective, replace
Protection degree: IP20
Segment: Power distribution
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: II
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 275 V
Low voltage network: Single-phase
Fuse: 16 A
Short-circuit current rating ISCCR: 1.5 kA
Protection level UP (typ.): ≤ 0.9 kV
Protection level Up at IN (L/N-PE): ≤ 1.5 kV
Leakage current at Un: 30 µA
Temporary surge voltage (over-voltage) - TOV: 440 V
Combined pulse UOC: 3 kV
Mains frequency at 250 Vmax: 50...60Hz
Number of poles: 1
PE conductor current IPE: 10 µA
Requirements category acc. to IEC 61643-11: Type III
Requirements class, acc. to EN 61643-11: T3
Response time: < 100μs
Signalling contact: No
Wire connection cross section, finely stranded, max.: 1 mm²
Long specification: Surge protection according to the requirements of Class III in accordance with IEC 61643-11, EN61643-11:2013. The arrestor serves as surge protection and is used in applications in accordance with IEC 61643-12. The arrestor is installed in the vicinity of the equipment that needs protection in a standard installation/distributor housing. The VPU III SO LD is earthed between the phase and the neutral conductor. With thermal separation device on the varistor. If there is no longer any protection, the red LED goes out. Rated voltage: 230 VAC In/max (8/20 µs): 1.5 kA protection level < 1.5 kV Type: Weidmüller VPU III R SO LD Order No. 1351680000 or equivalent
Short specification: Class III arrester with Uoc: 3 kV suitable for 230 V AC mains systems. Protection level < 1.5 kV. With red LED display, Type: Weidmüller VPU III SO LD Order no. 1351680000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VPU III SO LD
Order No.: 1351680000
GTIN (EAN): 4050118158472
Qty.: 1 pc(s).
Width: 12 mm
Width (inches): 0.472 inch
Height: 35 mm
Height (inches): 1.378 inch
Depth: 25 mm
Depth (inches): 0.984 inch
Net weight: 34 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 55 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...55 °C
Storage temperature: -40 °C...80 °C
Connection type: Miscellaneous
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black
Design: Flush mounting
Optical function display: Green LED = OK, Red LED = arrester is defective, replace
Protection degree: IP20
Segment: Power distribution
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: II
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 275 V
Low voltage network: Single-phase
Fuse: 16 A
Short-circuit current rating ISCCR: 1.5 kA
Protection level UP (typ.): ≤ 0.9 kV
Protection level Up at IN (L/N-PE): ≤ 1.5 kV
Leakage current at Un: 30 µA
Temporary surge voltage (over-voltage) - TOV: 440 V
Combined pulse UOC: 3 kV
Mains frequency at 250 Vmax: 50...60Hz
Number of poles: 1
PE conductor current IPE: 10 µA
Requirements category acc. to IEC 61643-11: Type III
Requirements class, acc. to EN 61643-11: T3
Response time: < 100μs
Signalling contact: No
Wire connection cross section, finely stranded, max.: 1 mm²
Long specification: Surge protection according to the requirements of Class III in accordance with IEC 61643-11, EN61643-11:2013. The arrestor serves as surge protection and is used in applications in accordance with IEC 61643-12. The arrestor is installed in the vicinity of the equipment that needs protection in a standard installation/distributor housing. The VPU III SO LD is earthed between the phase and the neutral conductor. With thermal separation device on the varistor. If there is no longer any protection, the red LED goes out. Rated voltage: 230 VAC In/max (8/20 µs): 1.5 kA protection level < 1.5 kV Type: Weidmüller VPU III R SO LD Order No. 1351680000 or equivalent
Short specification: Class III arrester with Uoc: 3 kV suitable for 230 V AC mains systems. Protection level < 1.5 kV. With red LED display, Type: Weidmüller VPU III SO LD Order no. 1351680000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,034 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m