1351580000
VPU III R 24V/4KV AC/DC
| Type: | VPU III R 24V/4KV AC/DC |
| Order No.: | 1351580000 |
| GTIN (EAN): | 4050118158557 |
| Qty.: | 1 pc(s). |
| Width: | 18 mm |
| Width (inches): | 0.709 inch |
| Height: | 102 mm |
| Height (inches): | 4.016 inch |
| Depth: | 71.5 mm |
| Depth (inches): | 2.815 inch |
| Net weight: | 84 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 70 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...70 °C |
| Rated current IN: | 16 A |
| Altitude: | ≤ 3000 m |
| Connection type: | Screw connection |
| Max. torque: | 0.5 Nm |
| Stripping length: | 5 mm |
| Cross-section for connected wire, solid core, min.: | 0.2 mm² |
| Cross-section for connected wire, solid core, max.: | 1.5 mm² |
| Altitude: | ≤ 3000 m |
| Colour: | orange |
| Design: | Installation housing; 1TE, Insta IP 20 |
| Optical function display: | Green LED = OK, Red LED = arrester is defective, replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Power distribution |
| UL 94 flammability rating: | V-0 |
| Version: | with remote contact |
| Pollution severity: | 2 |
| Surge voltage category: | II |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 32 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 32 V |
| Max. continuous voltage, Uc (DC): | 42 V |
| Low voltage network: | Single-phase |
| Discharge current, max. (8/20 µs): | 2 kA |
| Fuse: | 16 A |
| Short-circuit current rating ISCCR: | 1.5 kA |
| Protection level UP (typ.): | ≤ 220 V |
| Protection level Up at IN (L/N-PE): | ≤ 0.9 kV |
| Leakage current at Un: | 30 µA |
| Temporary surge voltage (over-voltage) - TOV: | 46 V |
| Combined pulse UOC: | 4 kV |
| Mains frequency at 250 Vmax: | 50...60Hz |
| Number of poles: | 1 |
| PE conductor current IPE: | 30 µA |
| Rated current IN: | 16 A |
| Requirements category acc. to IEC 61643-11: | Type III |
| Requirements class, acc. to EN 61643-11: | T3 |
| Response time: | ≤ 100 ns |
| Signalling contact: | 250 V 10 A 1 NC |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 7 mm |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.5 Nm |
| Clamping range, rated connection: | 2.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire cross-section, solid, min.: | 0.13 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.5 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 2.5 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 2.5 mm² |
| Long specification: | Surge protection according to the requirements of Class III in accordance with IEC 61643-11, EN61643-11:2013. The arrestor serves as surge protection and is used in applications in accordance with IEC 61643-12. The arrestor is installed in the vicinity of the equipment that needs protection in a standard installation/distributor housing. The VPU III R 24V is earthed between the phase and the neutral conductor. With thermal separation device on the varistor. If there is no longer any protection, the colour of the LEDs changes from green to red. The functional state is also displayed by a voltage-free signalling contact (NC contact). Rated voltage: 24 VAC/DC In/max (8/20 µs): 2 kA protection level < 0.89 kV load current Il: 16 A telecommunication output: contact NC: 250 V/0.5 A 48 VDC/0.1 A Type: Weidmüller VPU III R 24 V Order No. 1351580000 or equivalent |
| Short specification: | Class III arrester with Uoc: 4 kV suitable for 24 V AC/DC mains systems. Protection level < 0.89 kV. With remote alert Type: Weidmüller VPU III R 24 V/4 kV Order no. 1351580000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VPU III R 24V/4KV AC/DC |
| Order No.: | 1351580000 |
| GTIN (EAN): | 4050118158557 |
| Qty.: | 1 pc(s). |
| Width: | 18 mm |
| Width (inches): | 0.709 inch |
| Height: | 102 mm |
| Height (inches): | 4.016 inch |
| Depth: | 71.5 mm |
| Depth (inches): | 2.815 inch |
| Net weight: | 84 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 70 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...70 °C |
| Rated current IN: | 16 A |
| Altitude: | ≤ 3000 m |
| Connection type: | Screw connection |
| Max. torque: | 0.5 Nm |
| Stripping length: | 5 mm |
| Cross-section for connected wire, solid core, min.: | 0.2 mm² |
| Cross-section for connected wire, solid core, max.: | 1.5 mm² |
| Altitude: | ≤ 3000 m |
| Colour: | orange |
| Design: | Installation housing; 1TE, Insta IP 20 |
| Optical function display: | Green LED = OK, Red LED = arrester is defective, replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Power distribution |
| UL 94 flammability rating: | V-0 |
| Version: | with remote contact |
| Pollution severity: | 2 |
| Surge voltage category: | II |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 32 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 32 V |
| Max. continuous voltage, Uc (DC): | 42 V |
| Low voltage network: | Single-phase |
| Discharge current, max. (8/20 µs): | 2 kA |
| Fuse: | 16 A |
| Short-circuit current rating ISCCR: | 1.5 kA |
| Protection level UP (typ.): | ≤ 220 V |
| Protection level Up at IN (L/N-PE): | ≤ 0.9 kV |
| Leakage current at Un: | 30 µA |
| Temporary surge voltage (over-voltage) - TOV: | 46 V |
| Combined pulse UOC: | 4 kV |
| Mains frequency at 250 Vmax: | 50...60Hz |
| Number of poles: | 1 |
| PE conductor current IPE: | 30 µA |
| Rated current IN: | 16 A |
| Requirements category acc. to IEC 61643-11: | Type III |
| Requirements class, acc. to EN 61643-11: | T3 |
| Response time: | ≤ 100 ns |
| Signalling contact: | 250 V 10 A 1 NC |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 7 mm |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.5 Nm |
| Clamping range, rated connection: | 2.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire cross-section, solid, min.: | 0.13 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.5 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 2.5 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 2.5 mm² |
| Long specification: | Surge protection according to the requirements of Class III in accordance with IEC 61643-11, EN61643-11:2013. The arrestor serves as surge protection and is used in applications in accordance with IEC 61643-12. The arrestor is installed in the vicinity of the equipment that needs protection in a standard installation/distributor housing. The VPU III R 24V is earthed between the phase and the neutral conductor. With thermal separation device on the varistor. If there is no longer any protection, the colour of the LEDs changes from green to red. The functional state is also displayed by a voltage-free signalling contact (NC contact). Rated voltage: 24 VAC/DC In/max (8/20 µs): 2 kA protection level < 0.89 kV load current Il: 16 A telecommunication output: contact NC: 250 V/0.5 A 48 VDC/0.1 A Type: Weidmüller VPU III R 24 V Order No. 1351580000 or equivalent |
| Short specification: | Class III arrester with Uoc: 4 kV suitable for 24 V AC/DC mains systems. Protection level < 0.89 kV. With remote alert Type: Weidmüller VPU III R 24 V/4 kV Order no. 1351580000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,086 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |