1351220000
VPU II 2 PV 1000V DC
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU II 2 PV 1000V DC |
| Order No.: | 1351220000 |
| Version: | Surge voltage arrester, Low voltage, 1000 V, without telecomm. contact |
| GTIN (EAN): | 4050118158830 |
| Qty.: | 1 pc(s). |
| Width: | 35.6 mm |
| Width (inches): | 1.402 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 282 g |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 2TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Conditions and requirements: | EN 50539-11 |
| Discharge current In (8/20 µs): | 12.5 kA |
| Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE: | 1,000 V DC |
| PV system voltage, max. Ucpv: | 1,000 V |
| Protection level Up mode (+/-): | ≤ 5.6 kV |
| Protection level Up mode (-/PE): | ≤ 2.8 kV |
| Protection level Up mode(+/PE): | ≤ 2.8 kV |
| Requirements class: | Type II |
| Short-circuit curent ISCPV: | 200 A |
| Standards: | EN 50539-11 |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Multi-pole surge voltage arrestor according to the requirements of Class III acc. to IEC 50539-11. Consisting of V0 material, the arrestor serves as overvoltage protection in applications acc. to IEC 50539-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 1000 VDC In/max (8/20 µs): 12.5/25 kA, protection level < 2.8 kV, type: Weidmüller VPU II 2 PV 1000 V/25 kA, Order No. 1351220000 or equivalent |
| Short specification: | Class II arrester with In/Imax: 12.5/25 kA suitable for PV systems. Protection level < 2.8 kV. Type: Weidmüller VPU II 2 PV 1000 V/25 kA Order no. 1352200000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Delivery status: | This article will no longer be available in the future. |
| Available until: | 2020-05-01 |
| Type: | VPU II 2 PV 1000V DC |
| Order No.: | 1351220000 |
| Version: | Surge voltage arrester, Low voltage, 1000 V, without telecomm. contact |
| GTIN (EAN): | 4050118158830 |
| Qty.: | 1 pc(s). |
| Width: | 35.6 mm |
| Width (inches): | 1.402 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 282 g |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 2TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Conditions and requirements: | EN 50539-11 |
| Discharge current In (8/20 µs): | 12.5 kA |
| Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE: | 1,000 V DC |
| PV system voltage, max. Ucpv: | 1,000 V |
| Protection level Up mode (+/-): | ≤ 5.6 kV |
| Protection level Up mode (-/PE): | ≤ 2.8 kV |
| Protection level Up mode(+/PE): | ≤ 2.8 kV |
| Requirements class: | Type II |
| Short-circuit curent ISCPV: | 200 A |
| Standards: | EN 50539-11 |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Multi-pole surge voltage arrestor according to the requirements of Class III acc. to IEC 50539-11. Consisting of V0 material, the arrestor serves as overvoltage protection in applications acc. to IEC 50539-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 1000 VDC In/max (8/20 µs): 12.5/25 kA, protection level < 2.8 kV, type: Weidmüller VPU II 2 PV 1000 V/25 kA, Order No. 1351220000 or equivalent |
| Short specification: | Class II arrester with In/Imax: 12.5/25 kA suitable for PV systems. Protection level < 2.8 kV. Type: Weidmüller VPU II 2 PV 1000 V/25 kA Order no. 1352200000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,298 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |