Article image 1344720000

Weidmueller 1344720000

SAIH-SLL-3X1.0-16X0.5

Sensor/actuator line, Number of poles: 19, Shielded: No, LED: No, Sheath material: PUR, Halogen: No

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: SAIH-SLL-3X1.0-16X0.5
Order No.: 1344720000
Version: Sensor/actuator line, Number of poles: 19, Shielded: No, LED: No, Sheath material: PUR, Halogen: No
GTIN (EAN): 4050118146394
Qty.: 1 m
Net weight: 40 g
Operating temperature, max.: 80 °C
Operating temperature, min.: -25 °C
Number of poles: 19 (18 + PE)
Number of wires: 3
Wire cross section: 16 x 0.5 mm² + 3 x 1.0 mm²
Outside diameter: 11.6 mm ± 0.3 mm
Shielded: No
Insulation: TPM
Sheath material: PUR
Sheathing colour: black
Halogen: No
Temperature range, moving: -25...80 °C
Temperature range, stationary: -50...80 °C
Core in accordance with UL AWM style: 10493 (80 °C / 300 V)
Outer cladding in accordance with UL AWM style: 21198 (80 °C / 300 V)
Suitable for cable carriers: Yes
Torsion resistance: 0 °/m
Bending radius, min., stationary: 5 x cable diameter
Bending radius, min., moving: 10 x cable diameter
Bending cycles: 2 Mio
Resistant to welding beads: No
Hydrolysis and microbe resistant: Yes
LABS-free: Yes
Resistance to oils: Yes
ETIM 6.0: EC000830
ETIM 7.0: EC003249
eClass 9.0: 27-06-18-05
eClass 9.1: 27-06-90-90
eClass 10.0: 27-06-18-01
ROHS: Conform
Type: SAIH-SLL-3X1.0-16X0.5
Order No.: 1344720000
Version: Sensor/actuator line, Number of poles: 19, Shielded: No, LED: No, Sheath material: PUR, Halogen: No
GTIN (EAN): 4050118146394
Qty.: 1 m
Net weight: 40 g
Operating temperature, max.: 80 °C
Operating temperature, min.: -25 °C
Number of poles: 19 (18 + PE)
Number of wires: 3
Wire cross section: 16 x 0.5 mm² + 3 x 1.0 mm²
Outside diameter: 11.6 mm ± 0.3 mm
Shielded: No
Insulation: TPM
Sheath material: PUR
Sheathing colour: black
Halogen: No
Temperature range, moving: -25...80 °C
Temperature range, stationary: -50...80 °C
Core in accordance with UL AWM style: 10493 (80 °C / 300 V)
Outer cladding in accordance with UL AWM style: 21198 (80 °C / 300 V)
Suitable for cable carriers: Yes
Torsion resistance: 0 °/m
Bending radius, min., stationary: 5 x cable diameter
Bending radius, min., moving: 10 x cable diameter
Bending cycles: 2 Mio
Resistant to welding beads: No
Hydrolysis and microbe resistant: Yes
LABS-free: Yes
Resistance to oils: Yes
ETIM 6.0: EC000830
ETIM 7.0: EC003249
eClass 9.0: 27-06-18-05
eClass 9.1: 27-06-90-90
eClass 10.0: 27-06-18-01
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m