Article image 1176030000

Weidmueller 1176030000

ACT20M-UI-AO-S

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: ACT20M-UI-AO-S
Order No.: 1176030000
Version: Signal converter/insulator, Temperature converter, universal, 2-/3-/4- wire RTD, Thermocouple, Input : universal U, I, R,ϑ, Output : I / U
GTIN (EAN): 4032248970070
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 80 g
Humidity: 40 °C / 93 % rel. humidity, no condensation
Operating temperature, max.: 70 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...70 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 176 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor supply: > 15 V DC at 20 mA
Input voltage: configurable, 0(2)…10 V, 0(1)…5 V, 0…1 V DC, 0,2…1 V DC
Input resistance, voltage: > 10 MΩ
Input current: configurable, 0...20 mA, 4…20mA
Voltage drop, current input: < 3 V
Temperature input range: Configurable, min. measurement range 10°C (RTD), min. measurement range 50°C (TC), PT100: -200°C…850 °C, NI100: -60°C…+250 °C, TC type: B (0…+1820 °C), E: (-100…+1000 °C), J: (-100…+1200 °C), K: (-180…+1372 °C), L: (-200…+900 °C), N: (-180…+1300 °C), R: (-50…+1760 °C), S: (-50…+1760 °C), T: (-200…+400 °C), U: (-200…+600 °C), W3: (0…+2300 °C), W5: (0…+2300 °C), LR: (-200…+800 °C), Details under Downloads "Measuring range Table ACT20M-UI-AO"
Resistance: 0…10 kΩ
Potentiometer: 10…100 kΩ
Number of outputs: 1
Output voltage, note: configurable, 0(2)...10 V, 0(1)...5 V, 0(0,2)…1 V, 1…(0,2)0 V, 5…(1)0 V, 10…(2)0 V, downscale (0 V), upscale (11 V), in case of sensor error
Output current: configurable, 0...20 mA, 4...20 mA, 20…0 mA, 20…4 mA, downscale (3,5 mA), upscale (23 mA), in case of sensor error
Cut-off frequency (-3 dB): 100 Hz
cold junction compensation: internal
load impedance voltage: ≥ 10 kΩ
Load impedance current: ≤ 600 Ω, @ max 28mA
Accuracy: < 0.1 % of measuring range
Configuration: With FDT/DTM software
Galvanic isolation: 3-way isolator
Power consumption, max.: 1.2 W
Power consumption, typ.: 0.84 W
Rail: TS 35
Step response time: 400 ms (10...90%) @ U/I, 1 s @ temp
Temperature coefficient: ≤ 0.01 % / °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: 3-way isolator
Pollution severity: 2
Surge voltage category: II
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
Product information: The software configurable Universal Transmitter ACT20M-UI-AO-S separates and converts standard analogue signals. An analogue input signal (voltage, current, resistance, potentiometer, RTD, TC) is converted linear and galvanic isolated into an analogue output signal. The input may also operate as an active current loop (the loop current provided by the device). The power supply is galvanically isolated from input and output and happens via a direct wiring or the Weidmüller DIN Rail Bus (3-way isolation).
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-90
eClass 10.0: 27-21-01-20
ROHS: Conform
Type: ACT20M-UI-AO-S
Order No.: 1176030000
Version: Signal converter/insulator, Temperature converter, universal, 2-/3-/4- wire RTD, Thermocouple, Input : universal U, I, R,ϑ, Output : I / U
GTIN (EAN): 4032248970070
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 80 g
Humidity: 40 °C / 93 % rel. humidity, no condensation
Operating temperature, max.: 70 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...70 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 176 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor supply: > 15 V DC at 20 mA
Input voltage: configurable, 0(2)…10 V, 0(1)…5 V, 0…1 V DC, 0,2…1 V DC
Input resistance, voltage: > 10 MΩ
Input current: configurable, 0...20 mA, 4…20mA
Voltage drop, current input: < 3 V
Temperature input range: Configurable, min. measurement range 10°C (RTD), min. measurement range 50°C (TC), PT100: -200°C…850 °C, NI100: -60°C…+250 °C, TC type: B (0…+1820 °C), E: (-100…+1000 °C), J: (-100…+1200 °C), K: (-180…+1372 °C), L: (-200…+900 °C), N: (-180…+1300 °C), R: (-50…+1760 °C), S: (-50…+1760 °C), T: (-200…+400 °C), U: (-200…+600 °C), W3: (0…+2300 °C), W5: (0…+2300 °C), LR: (-200…+800 °C), Details under Downloads "Measuring range Table ACT20M-UI-AO"
Resistance: 0…10 kΩ
Potentiometer: 10…100 kΩ
Number of outputs: 1
Output voltage, note: configurable, 0(2)...10 V, 0(1)...5 V, 0(0,2)…1 V, 1…(0,2)0 V, 5…(1)0 V, 10…(2)0 V, downscale (0 V), upscale (11 V), in case of sensor error
Output current: configurable, 0...20 mA, 4...20 mA, 20…0 mA, 20…4 mA, downscale (3,5 mA), upscale (23 mA), in case of sensor error
Cut-off frequency (-3 dB): 100 Hz
cold junction compensation: internal
load impedance voltage: ≥ 10 kΩ
Load impedance current: ≤ 600 Ω, @ max 28mA
Accuracy: < 0.1 % of measuring range
Configuration: With FDT/DTM software
Galvanic isolation: 3-way isolator
Power consumption, max.: 1.2 W
Power consumption, typ.: 0.84 W
Rail: TS 35
Step response time: 400 ms (10...90%) @ U/I, 1 s @ temp
Temperature coefficient: ≤ 0.01 % / °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: 3-way isolator
Pollution severity: 2
Surge voltage category: II
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
Product information: The software configurable Universal Transmitter ACT20M-UI-AO-S separates and converts standard analogue signals. An analogue input signal (voltage, current, resistance, potentiometer, RTD, TC) is converted linear and galvanic isolated into an analogue output signal. The input may also operate as an active current loop (the loop current provided by the device). The power supply is galvanically isolated from input and output and happens via a direct wiring or the Weidmüller DIN Rail Bus (3-way isolation).
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-90
eClass 10.0: 27-21-01-20
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,091 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m