1161190000
VSPC 4SL 24VDC EX
| Type: | VSPC 4SL 24VDC EX |
| Order No.: | 1161190000 |
| Version: | Surge protection for instrumentation and control, 24 V, 300 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248950034 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 90 mm |
| Height (inches): | 3.543 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 51 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 43 |
| MTTF: | 2,665 Years |
| PFH in 1*10-9 per hour: | 8.9 |
| SFF: | 79.3 % |
| SIL in compliance with IEC 61508: | 2 |
| REACH SVHC: | Lead 7439-92-1 |
| ATEX - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| ATEX - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Certificate No. (ATEX): | KEMA10ATEX0148X |
| IECEx - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| IECEx - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Input power, max. PI: | 3 W |
| Input voltage, max. Ui: | 26 V |
| Internal capacity, max. CI: | < 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Temperature class T4/135°C (-40°C ... +85°C) li: | 350 mA |
| Temperature class T5/100°C (-40 ° C ... +75°C) li: | 250 mA |
| Temperature class T6/85 °C (-40 °C ... +60°C) li: | 250 mA |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 26 V |
| Internal capacity, max. CI: | 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | Light Blue |
| Design: | Terminal, miscellaneous |
| Optical function display: | No |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | without warning function / function indicator |
| protected binary signals: | 4 |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 24 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 26 V |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 10 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 2.5 kA |
| Standards: | IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Protection level UP (typ.): | 250 V |
| Protection level on output side Wire-PE 1kV/µs, typically: | 40 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 80 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 80 V |
| Protection level, UP GND - PE: | 60 V |
| Protection level, UP wire - PE: | 60 V |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Input voltage, max. Ui: | 26 V |
| Number of poles: | 2 |
| Overload - failure mode: | Modus 2 |
| Protection level, UP wire - wire: | 80 V |
| Pulse-reset capacity: | ≤ 30 ms |
| Rated current IN: | 300 mA |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Signal transmission properties (-3 dB): | 4 MHz |
| Signalling contact: | No |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 5 kA 8/20 μs |
| Surge current-carrying capacity C3: | 100 A 10/1000 μs |
| Surge current-carrying capacity D1: | 2.5 kA 10/350 μs |
| Volume resistance: | 4.7 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Long specification: | Surge protection plug for use in connection with the base element VSPC BASE 4SL FG for four wires with a common ground. Two-stage protection circuit in the plug consisting of coarse protection, decoupling resistors and fine protection between the signal wires and the signal ground/ground/earth. Suitable for intrinsically safe powered signal cables EX ia. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug. |
| Short specification: | Surge protection plugs for base element VSPC BASE 4SL FG, coarse and fine common mode voltage protection for four wires with a common signal ground for intrinsically safe signal cables EX ia. Version: 24 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSPC 4SL 24VDC EX |
| Order No.: | 1161190000 |
| Version: | Surge protection for instrumentation and control, 24 V, 300 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248950034 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 90 mm |
| Height (inches): | 3.543 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 51 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 43 |
| MTTF: | 2,665 Years |
| PFH in 1*10-9 per hour: | 8.9 |
| SFF: | 79.3 % |
| SIL in compliance with IEC 61508: | 2 |
| REACH SVHC: | Lead 7439-92-1 |
| ATEX - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| ATEX - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Certificate No. (ATEX): | KEMA10ATEX0148X |
| IECEx - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| IECEx - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Input power, max. PI: | 3 W |
| Input voltage, max. Ui: | 26 V |
| Internal capacity, max. CI: | < 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Temperature class T4/135°C (-40°C ... +85°C) li: | 350 mA |
| Temperature class T5/100°C (-40 ° C ... +75°C) li: | 250 mA |
| Temperature class T6/85 °C (-40 °C ... +60°C) li: | 250 mA |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 26 V |
| Internal capacity, max. CI: | 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | Light Blue |
| Design: | Terminal, miscellaneous |
| Optical function display: | No |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | without warning function / function indicator |
| protected binary signals: | 4 |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 24 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 26 V |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 10 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 2.5 kA |
| Standards: | IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Protection level UP (typ.): | 250 V |
| Protection level on output side Wire-PE 1kV/µs, typically: | 40 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 80 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 80 V |
| Protection level, UP GND - PE: | 60 V |
| Protection level, UP wire - PE: | 60 V |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Input voltage, max. Ui: | 26 V |
| Number of poles: | 2 |
| Overload - failure mode: | Modus 2 |
| Protection level, UP wire - wire: | 80 V |
| Pulse-reset capacity: | ≤ 30 ms |
| Rated current IN: | 300 mA |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Signal transmission properties (-3 dB): | 4 MHz |
| Signalling contact: | No |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 5 kA 8/20 μs |
| Surge current-carrying capacity C3: | 100 A 10/1000 μs |
| Surge current-carrying capacity D1: | 2.5 kA 10/350 μs |
| Volume resistance: | 4.7 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Long specification: | Surge protection plug for use in connection with the base element VSPC BASE 4SL FG for four wires with a common ground. Two-stage protection circuit in the plug consisting of coarse protection, decoupling resistors and fine protection between the signal wires and the signal ground/ground/earth. Suitable for intrinsically safe powered signal cables EX ia. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug. |
| Short specification: | Surge protection plugs for base element VSPC BASE 4SL FG, coarse and fine common mode voltage protection for four wires with a common signal ground for intrinsically safe signal cables EX ia. Version: 24 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,056 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |