Type: VSPC 2CL 24VAC R
Order No.: 1093400000
Version: Surge protection for instrumentation and control, 24 V, 24 V, 450 mA, IEC 61643-21, HART-compatible
GTIN (EAN): 4032248864317
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 98 mm
Height (inches): 3.858 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 46 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 45
MTTF: 2,537 Years
PFH in 1*10-9 per hour: 3.7
SFF: 95.27 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input voltage, max. Ui: 39 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: orange
Design: Terminal, miscellaneous
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: with warning function / function indicator
protected current loops: 2
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 24 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 28 V
Max. continuous voltage, Uc (DC): 40 V
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 2 x 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current, Iimp (10/350 µs) GND-PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire: 2.5 kA
Fuse: 0.5 A
Standards: IEC 61643-21, HART-compatible
Protection level UP (typ.): < 800 V
Protection level on output side Wire-PE 1kV/µs, typically: 450 V
Protection level on output side Wire-wire 1 kV/µs, typically: 60 V
Protection level on output side Wire-wire 8/20 µs, typically: 60 V
Protection level, UP GND - PE: 800 V
Protection level, UP wire - PE: 450 V
Capacitance: 2.0 nF
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 60 V
Pulse-reset capacity: ≤ 450 ms
Rated current IN: 450 mA
Requirements category acc. to IEC 61643-21: C1, C2, C3, D1
Signal transmission properties (-3 dB): 2.7 MHz
Surge current-carrying capacity C1: < 1 kA 8/20 μs
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: 2.20 Ω
Type of connection: Pluggable in VSPC BASE
Long specification: Surge protection plug for use in connection with the base element VSPC BASE 2CL R for two floating-ground driven paired cables with integrated status display and remote monitoring option.Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
Short specification: Surge protection plug for base element VSPC BASE 2CL R with integrated status indicator and remote monitoring option, transverse voltage coarse and fine protection for two floating-ground powered paired cables and alert function, coarse common mode voltage protection to earth.Version: 24 V AC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSPC 2CL 24VAC R
Order No.: 1093400000
Version: Surge protection for instrumentation and control, 24 V, 24 V, 450 mA, IEC 61643-21, HART-compatible
GTIN (EAN): 4032248864317
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 98 mm
Height (inches): 3.858 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 46 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 45
MTTF: 2,537 Years
PFH in 1*10-9 per hour: 3.7
SFF: 95.27 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input voltage, max. Ui: 39 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: orange
Design: Terminal, miscellaneous
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: with warning function / function indicator
protected current loops: 2
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 24 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 28 V
Max. continuous voltage, Uc (DC): 40 V
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 2 x 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current, Iimp (10/350 µs) GND-PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire: 2.5 kA
Fuse: 0.5 A
Standards: IEC 61643-21, HART-compatible
Protection level UP (typ.): < 800 V
Protection level on output side Wire-PE 1kV/µs, typically: 450 V
Protection level on output side Wire-wire 1 kV/µs, typically: 60 V
Protection level on output side Wire-wire 8/20 µs, typically: 60 V
Protection level, UP GND - PE: 800 V
Protection level, UP wire - PE: 450 V
Capacitance: 2.0 nF
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 60 V
Pulse-reset capacity: ≤ 450 ms
Rated current IN: 450 mA
Requirements category acc. to IEC 61643-21: C1, C2, C3, D1
Signal transmission properties (-3 dB): 2.7 MHz
Surge current-carrying capacity C1: < 1 kA 8/20 μs
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: 2.20 Ω
Type of connection: Pluggable in VSPC BASE
Long specification: Surge protection plug for use in connection with the base element VSPC BASE 2CL R for two floating-ground driven paired cables with integrated status display and remote monitoring option.Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
Short specification: Surge protection plug for base element VSPC BASE 2CL R with integrated status indicator and remote monitoring option, transverse voltage coarse and fine protection for two floating-ground powered paired cables and alert function, coarse common mode voltage protection to earth.Version: 24 V AC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,047 kg