1065020000
VSSC6 RS485 PA EX
| Type: | VSSC6 RS485 PA EX |
| Order No.: | 1065020000 |
| Version: | Surge protection for instrumentation and control, 12 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248830251 |
| Qty.: | 1 pc(s). |
| Width: | 12.4 |
| Width (inches): | 0.488 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 56 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 29 |
| MTTF: | 3,936 Years |
| PFH in 1*10-9 per hour: | 1.75 |
| SFF: | 93.97 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| ATEX - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| ATEX - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| IECEx - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| IECEx - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Input power, max. PI: | 0.75 W |
| Input voltage, max. Ui: | 35 V |
| Internal capacity, max. CI: | 1 nF |
| Internal inductance, max. LI: | 0 µH |
| Temperature class T4/135°C (-40°C ... +120 °C) li: | 300 mA |
| Temperature class T5/100°C (-40 ° C ... +85 °C) li: | 300 mA |
| Temperature class T6/85 °C (-40 °C ... +70 °C) li: | 300 mA |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 300 mA |
| Input voltage, max. Ui: | 35 V |
| Internal capacity, max. CI: | 1 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | Light Blue |
| Design: | Terminal |
| Isolating function: | No |
| Optical function display: | No |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 12 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 35 V |
| Discharge current, max. (8/20 µs): | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 5 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 5 kA |
| Lightning test current Iimp (10/350 µs): | 0.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 0.5 kA |
| Standards: | IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Protection level UP (typ.): | ≤ 2 kV |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Input voltage, max. Ui: | 35 V |
| Insertion loss: | 250 MHz |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Pulse-reset capacity: | ≤ 15 ms |
| Rated current IN: | 300 mA |
| Requirements category acc. to IEC 61643-21: | C2, C3, D1 |
| Signal transmission properties (-3 dB): | 113.6 MHz |
| Surge current-carrying capacity C2: | 2.5 kA 8/20 µs 5 kV 1.2/50 µs |
| Surge current-carrying capacity C3: | 10 A 10/1000 µs |
| Surge current-carrying capacity D1: | 0.5 kA 10/350 μs |
| Volume resistance: | 1.8 Ω 10 % |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 422 / RS 485 Profibus PA signal circuit with 12 V DC, 2-wire technology. A RS 422 / RS 485 data signal with max. 0.6A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 422 / RS 485 Profibus signal circuit with 2-wire technology. Version: 12V DC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSSC6 RS485 PA EX |
| Order No.: | 1065020000 |
| Version: | Surge protection for instrumentation and control, 12 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248830251 |
| Qty.: | 1 pc(s). |
| Width: | 12.4 |
| Width (inches): | 0.488 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 56 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 29 |
| MTTF: | 3,936 Years |
| PFH in 1*10-9 per hour: | 1.75 |
| SFF: | 93.97 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| ATEX - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| ATEX - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| IECEx - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| IECEx - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Input power, max. PI: | 0.75 W |
| Input voltage, max. Ui: | 35 V |
| Internal capacity, max. CI: | 1 nF |
| Internal inductance, max. LI: | 0 µH |
| Temperature class T4/135°C (-40°C ... +120 °C) li: | 300 mA |
| Temperature class T5/100°C (-40 ° C ... +85 °C) li: | 300 mA |
| Temperature class T6/85 °C (-40 °C ... +70 °C) li: | 300 mA |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 300 mA |
| Input voltage, max. Ui: | 35 V |
| Internal capacity, max. CI: | 1 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | Light Blue |
| Design: | Terminal |
| Isolating function: | No |
| Optical function display: | No |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 12 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 35 V |
| Discharge current, max. (8/20 µs): | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 5 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 5 kA |
| Lightning test current Iimp (10/350 µs): | 0.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 0.5 kA |
| Standards: | IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Protection level UP (typ.): | ≤ 2 kV |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Input voltage, max. Ui: | 35 V |
| Insertion loss: | 250 MHz |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Pulse-reset capacity: | ≤ 15 ms |
| Rated current IN: | 300 mA |
| Requirements category acc. to IEC 61643-21: | C2, C3, D1 |
| Signal transmission properties (-3 dB): | 113.6 MHz |
| Surge current-carrying capacity C2: | 2.5 kA 8/20 µs 5 kV 1.2/50 µs |
| Surge current-carrying capacity C3: | 10 A 10/1000 µs |
| Surge current-carrying capacity D1: | 0.5 kA 10/350 μs |
| Volume resistance: | 1.8 Ω 10 % |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 422 / RS 485 Profibus PA signal circuit with 12 V DC, 2-wire technology. A RS 422 / RS 485 data signal with max. 0.6A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 422 / RS 485 Profibus signal circuit with 2-wire technology. Version: 12V DC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,077 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |