Article image 1064990000

Weidmueller 1064990000

VSSC6 RS232

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: VSSC6 RS232
Order No.: 1064990000
Version: Surge protection for instrumentation and control, 12 V, 500 mA, IEC 61643-21
GTIN (EAN): 4032248830237
Qty.: 10 pc(s).
Width: 6.2 mm
Width (inches): 0.244 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 40.2 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 76
MTTF: 1,502 Years
PFH in 1*10-9 per hour: 3.5
SFF: 95.39 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Input current, max. II: 500 mA
Internal capacity, max. CI: 7 nF
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (DC): 12 V
Voltage type: AC
Max. continuous voltage, Uc (DC): 15 V
Discharge current, max. (8/20 µs): 20 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current Iimp (10/350 µs): 0.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Standards: IEC 61643-21
Protection level UP (typ.): ≤ 100 V
Insertion loss: 1.43 Mhz
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 15 ms
Rated current IN: 500 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 1.4 MHz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 10 A 10/1000 µs
Surge current-carrying capacity D1: 0.5 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 232 signal circuit with 12 V DC, 2-wire technology. A RS 232 data signal with max. 0.6A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 232 signal circuit with 2-wire technology. Version: 12V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSSC6 RS232
Order No.: 1064990000
Version: Surge protection for instrumentation and control, 12 V, 500 mA, IEC 61643-21
GTIN (EAN): 4032248830237
Qty.: 10 pc(s).
Width: 6.2 mm
Width (inches): 0.244 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 40.2 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 76
MTTF: 1,502 Years
PFH in 1*10-9 per hour: 3.5
SFF: 95.39 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Input current, max. II: 500 mA
Internal capacity, max. CI: 7 nF
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (DC): 12 V
Voltage type: AC
Max. continuous voltage, Uc (DC): 15 V
Discharge current, max. (8/20 µs): 20 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current Iimp (10/350 µs): 0.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Standards: IEC 61643-21
Protection level UP (typ.): ≤ 100 V
Insertion loss: 1.43 Mhz
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 15 ms
Rated current IN: 500 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 1.4 MHz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 10 A 10/1000 µs
Surge current-carrying capacity D1: 0.5 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 232 signal circuit with 12 V DC, 2-wire technology. A RS 232 data signal with max. 0.6A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a RS 232 signal circuit with 2-wire technology. Version: 12V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,044 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m