Type: VSSC6 TRLDMOV120VAC/DC
Order No.: 1064840000
Version: Surge protection for instrumentation and control, 120 V, 170 V, 12 A, IEC 61643-21
GTIN (EAN): 4032248830091
Qty.: 5 pc(s).
Width: 12.4
Width (inches): 0.488 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 62.8 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 37
MTTF: 3,085 years
PFH in 1*10-9 per hour: 0.9
SFF: 97.57 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 12 A
Input voltage, max. Ui: 212 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: Yes
Optical function display: Yes
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
Testing option: Functional screw with test plug receptacle, connections 1, 2, 4, 5
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 120 V
Rated voltage (DC): 170 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 150 V
Max. continuous voltage, Uc (DC): 212 V
Discharge current, max. (8/20 µs): 12 kA
Discharge current In (8/20µs) wire-PE: 1.5 kA
Discharge current Imax (8/20µs) wire-PE: 6 kA
Standards: IEC 61643-21
Protection level UP (typ.): < 600 V
Capacitance: 283 pF
Number of poles: 1
Overload - failure mode: Mode 1
Rated current IN: 12 A
Requirements category acc. to IEC 61643-21: C1, C2
Surge current-carrying capacity C1: 0.5 kA 8/20 µs 1 kV 1.2/50 µs
Surge current-carrying capacity C2: 1.5 kA 8/20 μs
Volume resistance: < 0.1 Ω
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Feed-through terminal, 6.2mm wide with varistors between the two signal lines and the mounting rail potential, TS 35 contact base.Each signal path can be opened using an isolator. A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Feed-through terminal with varistors (MOV) between two signal lines and mounting rail potential. Each signal path can be opened using an isolator. TS 35 contact base. Version: 120 V UC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform
Type: VSSC6 TRLDMOV120VAC/DC
Order No.: 1064840000
Version: Surge protection for instrumentation and control, 120 V, 170 V, 12 A, IEC 61643-21
GTIN (EAN): 4032248830091
Qty.: 5 pc(s).
Width: 12.4
Width (inches): 0.488 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 62.8 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 37
MTTF: 3,085 years
PFH in 1*10-9 per hour: 0.9
SFF: 97.57 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 12 A
Input voltage, max. Ui: 212 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: Yes
Optical function display: Yes
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
Testing option: Functional screw with test plug receptacle, connections 1, 2, 4, 5
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 120 V
Rated voltage (DC): 170 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 150 V
Max. continuous voltage, Uc (DC): 212 V
Discharge current, max. (8/20 µs): 12 kA
Discharge current In (8/20µs) wire-PE: 1.5 kA
Discharge current Imax (8/20µs) wire-PE: 6 kA
Standards: IEC 61643-21
Protection level UP (typ.): < 600 V
Capacitance: 283 pF
Number of poles: 1
Overload - failure mode: Mode 1
Rated current IN: 12 A
Requirements category acc. to IEC 61643-21: C1, C2
Surge current-carrying capacity C1: 0.5 kA 8/20 µs 1 kV 1.2/50 µs
Surge current-carrying capacity C2: 1.5 kA 8/20 μs
Volume resistance: < 0.1 Ω
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Feed-through terminal, 6.2mm wide with varistors between the two signal lines and the mounting rail potential, TS 35 contact base.Each signal path can be opened using an isolator. A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Feed-through terminal with varistors (MOV) between two signal lines and mounting rail potential. Each signal path can be opened using an isolator. TS 35 contact base. Version: 120 V UC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,063 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m