Article image 1064150000

Weidmueller 1064150000

VSSC6 CL 12VDC 0.5A

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: VSSC6 CL 12VDC 0.5A
Order No.: 1064150000
Version: Surge protection for instrumentation and control, 12 V, 500 mA, IEC 61643-21, HART-compatible
GTIN (EAN): 4032248829545
Qty.: 10 pc(s).
Width: 6.2 mm
Width (inches): 0.244 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 40.6 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 19
MTTF: 6,008 Years
PFH in 1*10-9 per hour: 1.95
SFF: 89.74 %
SIL in compliance with IEC 61508: 2
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 500 mA
Input voltage, max. Ui: 15 V
Internal capacity, max. CI: 1 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (DC): 12 V
Voltage type: DC
Max. continuous voltage, Uc (DC): 15 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 5 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 5 kA
Lightning test current Iimp (10/350 µs): 0.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Fuse: 0.5 A
Standards: IEC 61643-21, HART-compatible
Protection level UP (typ.): 900 V
Protection level on output side Wire-wire 1 kV/µs, typically: 30 V
Insertion loss: 250 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 35 V
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 500 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): ≤ 700 kHz
Surge current-carrying capacity C2: 2.5 kA
Surge current-carrying capacity C3: 50 A
Surge current-carrying capacity D1: 0,5 kA
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a floating-ground signal circuit with 12 V DC, 2-wire technology. A current loop with max. 0.6A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a floating-ground driven signal circuit with 2-wire technology and a common wire. Version: 12V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSSC6 CL 12VDC 0.5A
Order No.: 1064150000
Version: Surge protection for instrumentation and control, 12 V, 500 mA, IEC 61643-21, HART-compatible
GTIN (EAN): 4032248829545
Qty.: 10 pc(s).
Width: 6.2 mm
Width (inches): 0.244 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 40.6 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 19
MTTF: 6,008 Years
PFH in 1*10-9 per hour: 1.95
SFF: 89.74 %
SIL in compliance with IEC 61508: 2
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 500 mA
Input voltage, max. Ui: 15 V
Internal capacity, max. CI: 1 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (DC): 12 V
Voltage type: DC
Max. continuous voltage, Uc (DC): 15 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 5 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 5 kA
Lightning test current Iimp (10/350 µs): 0.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Fuse: 0.5 A
Standards: IEC 61643-21, HART-compatible
Protection level UP (typ.): 900 V
Protection level on output side Wire-wire 1 kV/µs, typically: 30 V
Insertion loss: 250 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 35 V
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 500 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): ≤ 700 kHz
Surge current-carrying capacity C2: 2.5 kA
Surge current-carrying capacity C3: 50 A
Surge current-carrying capacity D1: 0,5 kA
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a floating-ground signal circuit with 12 V DC, 2-wire technology. A current loop with max. 0.6A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for a floating-ground driven signal circuit with 2-wire technology and a common wire. Version: 12V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,044 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m