Type: VSSC4 GDT 24VAC/DC 20kA
Order No.: 1064030000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 20 A, IEC 61643-21
GTIN (EAN): 4032248829446
Qty.: 5 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 37.8 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 10
MTTF: 11,416 years
PFH in 1*10-9 per hour: 0
SFF: 100 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 20 A
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 20 kA
Discharge current In (8/20µs) wire-PE: 5 kA
Discharge current Imax (8/20µs) wire-PE: 20 kA
Lightning test current Iimp (10/350 µs): 2.5 kA
Standards: IEC 61643-21
Protection level UP (typ.): < 1000 V
Capacitance: 4.96 pF
Number of poles: 1
Overload - failure mode: Modus 2
Rated current IN: 20 A
Requirements category acc. to IEC 61643-21: C2, C3, D1
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: < 0.1 Ω
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Feed-through terminal, 12.4mm wide with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base.A signal with max. 32A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Feed-through terminal with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base. Version: 24V AC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform
Type: VSSC4 GDT 24VAC/DC 20kA
Order No.: 1064030000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 20 A, IEC 61643-21
GTIN (EAN): 4032248829446
Qty.: 5 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 37.8 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 10
MTTF: 11,416 years
PFH in 1*10-9 per hour: 0
SFF: 100 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 20 A
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 20 kA
Discharge current In (8/20µs) wire-PE: 5 kA
Discharge current Imax (8/20µs) wire-PE: 20 kA
Lightning test current Iimp (10/350 µs): 2.5 kA
Standards: IEC 61643-21
Protection level UP (typ.): < 1000 V
Capacitance: 4.96 pF
Number of poles: 1
Overload - failure mode: Modus 2
Rated current IN: 20 A
Requirements category acc. to IEC 61643-21: C2, C3, D1
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: < 0.1 Ω
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Feed-through terminal, 12.4mm wide with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base.A signal with max. 32A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Feed-through terminal with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base. Version: 24V AC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,038 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m