Article image 1063890000

Weidmueller 1063890000

VSSC4 SL FG24VAC/DC0.5A

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Type: VSSC4 SL FG24VAC/DC0.5A
Order No.: 1063890000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 500 mA, IEC 61643-21
GTIN (EAN): 4032248829323
Qty.: 10 pc(s).
Width: 6.2 mm
Width (inches): 0.244 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 27 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 43
MTTF: 2,655 Years
PFH in 1*10-9 per hour: 0.9
SFF: 97.91 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 500 mA
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Lightning test current Iimp (10/350 µs): 1 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Fuse: 0.5 A
Standards: IEC 61643-21
Protection level UP (typ.): 150 V
Dielectric strength at FG against PE: ≥ 500 V
Insertion loss: 3.42 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 500 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 3.4 MHz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 10 A 10/1000 µs
Surge current-carrying capacity D1: 1 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits with 24 V UC. When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits. Version: 24V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSSC4 SL FG24VAC/DC0.5A
Order No.: 1063890000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 500 mA, IEC 61643-21
GTIN (EAN): 4032248829323
Qty.: 10 pc(s).
Width: 6.2 mm
Width (inches): 0.244 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 27 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 43
MTTF: 2,655 Years
PFH in 1*10-9 per hour: 0.9
SFF: 97.91 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
Certificate No. (UL): E311081
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 500 mA
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: black
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Lightning test current Iimp (10/350 µs): 1 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Fuse: 0.5 A
Standards: IEC 61643-21
Protection level UP (typ.): 150 V
Dielectric strength at FG against PE: ≥ 500 V
Insertion loss: 3.42 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 500 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 3.4 MHz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 10 A 10/1000 µs
Surge current-carrying capacity D1: 1 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits with 24 V UC. When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification: Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits. Version: 24V DC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Parametry logistyczne

ECCN:
Kraj pochodzenia:
EAN:
Waga: 0,03 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m